Dynamic Reconfiguration User's Guide 2.5.1
|
Contents

|
5.1.1 DR attach
If DR attach fails, follow these instructions.
- In case DR attach fails with "recovery fails". (system board status is "Configured" )
Please detach the system board first. Then find out the root cause and try to resolve it according to Chapter 6, "Messages and DR Error Conditions on Solaris 8 OS" and Chapter 7, "Messages and DR Error Conditions on Solaris 9 OS and Solaris 10 OS". After the error is eliminated, retry DR attach.
- In case DR attach fails with "recovery successes". (system board status is "Waiting" )
Please retry DR attach or run DR detach to return the system board status to a valid status.
- In case DR attach seemed to finish successfully but some connection scripts showed error messages. (system board status is "Configured")
Find out the cause of the error and resolve it according to the connection script error messages