Enhanced Support Facility 2.5.1 Update Information
Contents Previous

Chapter 2 Modification

Bugs found in the software of previous version levels are fixed.

See the following table 2.1 for details of the bugs and their P-number.

Table 2.1

Version Level

Component

Correction number

Content of correction or Corrected Bug

2.5.1

Machine Administration

PG38134

The illegal message occurred in the syslog when the memory collectable error is occurred.

PG38119

Improvement of power control with target disk which tries to replace in Hot Swapping Guide.

PG36384

The address 0.0.0.0 that means the wild-card, cannot be input in the SNMP Administration menu on PRIMEPOWER250/450.

PG39077

The frequency of CPU displayed in Display Hardware Error Log menu is mistaken on PRIMEPOWER650/850.

PG37816

Disk information might not be displayed on the hrdconf command on the system which runs Solaris10.

PG37964

PCI information is mistaken by the hrdconf command for Solaris9/10 on PRIMEPOWER650/850/900/1500/2500/HPC2500.

PG38179

The removable device mark cleared when reset hardware failure at this device by Management of Hardware Error Event menu.

PG39870

The PCI card configuration information is wrong in Server System Manager.

Remote Support

PG37335

When the HTTP communication is canceled, the REMCS agent doesn't respond occasionally.

PG39370

When the HTTP abnormal connection is repeated, the REMCS agent might not be able to open the file.

PG40322

REMCS API does not return rarely.

SunVTS,
FJVTS

PG36012

The fjcputest failed in the floating point unit test.

PG37234

When the fjcputest is executed on Solaris 10, the program failed with core dumped.

Server Default Configuration

PG41048

Installation scripts in package, r.manifest and preremove

have been modified due to "-C" option had been missing

for svcprop(1) in the script. The contents of package

except the installation scripts has not been changed.

G-LAN error notification

PG41520

When ESF is installed by the custom jump start,the "Killed" message is displayed by installing the FJSVgidad.us package.

2.5

DR command

PG29523

Disconnecting board fails with "Invalid Status Device=Memory Status=NULL."

NGDR command

PG28272

The board can't be disconnected once disconnecting kernel board is failed.

PG28274

Disconnecting board is failed when no-obp-sb is set.

PG28380

CPU is still offline after disconnecting board is failed.

SCF driver

PG33692

In the environment by which UPS is connected, the power recovery processing is not correctly done when a momentary power failure occurs, and the system does shutdown occasionally.

PG31442

The function of the Fault LED control of extended file unit (PW007FL2/PW007FL2U) is added.

PG29871

Group ID of the /opt/FJSVhwr/sbin/fjprtdiag command was changed from 'root' to 'sys.

PG30956

In PRIMEPOWER 650/850/900/1500/2500/HPC2500,
"WARNING: interrupt level 9 not serviced" might be output in system operation, SCF driver is changed.

PG31447

When CPU (SPARV64 V) of 2GHz or more is installed in
PRIMEPOWER 650/850/900/1500/2500/HPC2500, the CPU frequency of the fjprtdiag(1M) command is displayed by a minus value.

PG29396

Group ID of the /opt/FJSVhwr/sbin/fjprtdiag command was changed from 'root' to 'sys.

P806854

Group ID of the /opt/FJSVhwr/sbin/fjprtdiag command was changed from 'root' to 'sys.

PG31419

The function of the Fault LED control of extended file unit (PW007FL2/PW007FL2U) is added.

PG31421

When CPU (SPARV64 V) of 2GHz or more is installed, the CPU frequency of the fjprtdiag(1M) command is displayed by a minus value.

Machine Administration

PG27214

Some of mphd driver's error message cannot be detected in PRIMEPOWER650/850/900/1500/2500/HPC2500.

P806678

The setrci command dumps core on PRIMEPOWER1/100/200/ 400/600, GP7000F Model200/200R/400/400R/400A/600/600R, FUJITSU S series and GP7000S series.

PG30414

A new type of CPU supported.

PG30413

The error mark of panic cannot resetted.

PG30412

The serial port device information may not display on PRIMEPOWER650/850.

PG30411

The memory module failure not reported. if failure memory module mounted on DR-added System board.

PG28416

DR may stop by picld restart fail.

PG28417

The setrci command may core dumped.

PG28044

The CPU mask value display format is wrong on 1560MHz or 1620MHz type SPARC64V.

PG28046

The TTY and onboard LAN device is not displayed in configuration display menu on PRIMEPOWER2500/HPC2500.

PG28047

The communication between ESF(Enhanced Support facikity) and SCS(System Console Software) is failed on PRIMEPOWER900/1500/2500/HPC2500.

PG27969

When the NFS mount to SMC fails, it cannot be judged from the message of PRIMEPOWER900/1500/2500/HPC2500.

PG27111

The SCSI-ID of failure unit displayed by hexa-decimal number.

PG27113

The Notification to PRIMEPOWER Server Manager when PSU(Power Supply Unit in PCIBOX)exchanged.

PG27114

The hardware failure mark vanished when system boot.

PG27117

The removable device mark cleared when reset hardware failure at this device.

PG28494

The hardware configuration information management Daemon might dump core after executing PCI Hot-plug in PRIMEPOWER450.

PG28496

The mark of "(sfdsk)" for the disk managed with SynfinityDisk or PRIMECLUSTER/GDS might not be displayed in hardware configuration information, or the hardware configuration information management daemon might dump core in PRIMEPOWER250/450.

PG28740

When the signal is received, the command termination might not be correctly executed on PRIMEPOWER250/450.

PG35532

A new message of Solaris 7,8,9 is supported.

PG31493

A preventive maintenance and an automatic disk drive power supply off function were supported in Hot Swapping Guide.

PG33902

The error mail is notified every about 30 minutes on PRIMEPOWER900/1500/2500/HPC2500

PG32837

The message that the console path was switched might be displayed on the System Management Console on PRIMEPOWER900/1500/2500/HPC2500.

PG33187

Spell miss in power log display command on PRIMEPOWER650/850

PG32037

The FAN unit (in RCI-device) failure may be misdetected on PRIMEPOWER900/1500/2500/HPC2500

PG32038

The prterrlog command may displays multiple line of 'VERSION' information.

PG32040

The error mark not set when UPS failure detected.

PG32035

The CPU and memory statistics information collection function is supported.

PG32036

The New menu (Management of Hardware Error Event) supported.

PG32560

The PCI card configuration information is wrong in REMCS.

PG32649

Spell miss in power log display menu and error log display command.
(Factor->Facter, Apr->Apl)

P806678

The setrci command dumps core on PRIMEPOWER1/100/200/400/600, GP7000F Model200/200R/400/400R/400A/600/600R,FUJITSU S series and GP7000S series.

PG33125

The hrdconf command does not display the tape device other than "st" in PRIMEPOWER250/450.

PG33369

The hcd daemon dumps core in the root directory on PRIMEPOWER250/450.

PG28740

When the signal is received, the command termination might not be correctly executed on PRIMEPOWER250/450.

PG28494

The hardware configuration information management daemon might dump core after executing PCI Hot-plug in PRIMEPOWER450.

PG28496

The mark of "(sfdsk)" for the disk managed with SynfinityDisk or PRIMECLUSTER/GDS might not be displayed in hardwareconfiguration information, or the hardware configuration information management daemon might dump core in PRIMEPOWER250/450.

PG27214

Some of mphd driver's error message cannot be detected in PRIMEPOWER650/850/900/1500/2500/HPC2500.

Remote Support

PG31535

The hardware configuration information of new CPU(1.89GHz,2.16GHz) is supported.

PG30430

The error generating count of CPU and memory is added to the statistics information notified to a REMCS center.

P806683

A software configuration information may not be sent.

P807255

HPC downloading function cannot be disabled.

PG36802

When the system panic will occur on the PRIMEPOWER650/850, remote.conf file may be broken.

2.4.1

NGDR command

PG20488

Support for Dynamic Reconfiguration on PRIMEPOWER 900/1500/2500.

SCF driver

PG14495

When the GP7000F Model 200/200R/400/400R/400A/600/600R and PRIMEPOWER200/400/600, the Fault LED control of extended file unit (PW007FL2/PW007FL2U) is supported in the diskadm command.

PG22262

When the window is closed while executing DR operation from
the terminal , panic might be done

PG22264

In PRIMEPOWER900/1500/2500/HPC2500, the DR operation by the drc command might fail in the system board set in the XSB mode, and the display result of the drcstat command be displayed in the PSB mode.

PG19875

There are a lot of memory utilizations of the fjprtdiag command
when large-scale composing

PG20070

When openeepr driver's patch 110918-04 is applied, the
Performance of the fjprtdiag command is deteriorated.

PG18784

The display result of fjprtdiag generates the column gap.

PG18852

Fjprtdiag command outputs core.

PG22671

Correction of fjprtdevice command according to PRIMEPOWER
250 rackmounting type (4U) model addition.

PG20708

Support of PRIMEPOWER250/450 DC model.

PG20365

When the PRIMEPOWER250/450, command addition for
Option data registration for OEM which is new function of SCF.

PG18863

The display result of of fjprtdiag generates the column gap.

PG18864

Fjprtdiag command outputs core.

PG20704

When the PRIMEPOWER250/450, FANTRAY is made not to be displayed in the SCF driver message in abnormal
circumstances of FAN.

PG20706

When the PRIMEPOWER250/450, the setting is enabled at the watch time of SCF after it interrupts of REQUEST.

PG20363

When the PW250/450, correction of SCF driver according to new addition of SCF support function flag.

PG19874

In PRIMEPOWER250/450, when it is reported power failure, power restore, UPS failure, UPS low battery from excluding self device in the RCI composition, the message display is mistaken.

PG19155

When the PRIMEPOWER250/450, Ebus time-out is generated by SCF reset.

P805358

In PRIMEPOWER1/100, OS panic occurs when the
interruption without the factor is generated.

PG22265

When the window is closed while executing DR operation from
the terminal, panic might be done.

PG20050

Fjprtdiag command outputs core.

PG20051

There are a lot of memory utilizations of the fjprtdiag command
When large-scale composing.

PG20073

When openeepr driver's patch 110918-04 is applied, the
Performance of the fjprtdiag command is deteriorated.

PG20336

In GP7000F Model 200/200R/400/400R/400A/600/600R and
PRIMEPOWER200/400/600, "WARNING: FJSVscf: scf cmd
(0x?) incomplete" is displayed on the console.

PG22392

The PRIMEPOWER CoD function was supported for
PRIMEPOWER900/1500/2500 Cod models.

Sunvts,
FJSVvts

4339802

disktest fails with multiple instances accessing same parity.

4489875

disktest issues a timeout error if fun with multiple instance.

4494434

VTS 4.5 device tree lists non-existent ssc100 device.

4508028

netlbtest creates a tmpfile in local dir.

4513810

ifbtest needs to allow for different sizes of display list memory.

4513580

Timed out trying to get a lock on blocks.

4494602

disktest on Monterey produces failure.

4532672

ifb-lite+ sunvts "segmentation violation" while testing display.

4519508

SunVTS 4.5 pmemtest missing ECC report and Section ID
Option.

4521847

The message that is received when a fan cannister or a power.

4546447

sunvts 4.5 ifbtest fails on Serengeti with 4 IFB cards.

4522835

Disktest does not achieve a pass with the 12 hrs profile for high
config systems.

4508863

env5test.init_picl_sem.FATAL env /psvc_semaphore failed in
sem_open.

4757224

pmemtest fails on systems with Solaris 8 kernel patch 108528-16(KU16).

4641737

cputest missing if cpu-id >= 128.

Machine Administration

PG22765

The new mode PRMEPOWER250 4U rack-mount type is supported.

PG21851

Improvement of notification e-mail format in
PRIMEPOWER250/450.

PG21853

The REMCS function of extended System Control Facility (XSCF) is supported in PRIMEPOWER250/450.

PG21863

When the log directory does not exist, the collection of log fails
in PRIMEPOWER250/450.

PG21864

The function to set the hostname of the SMTP server and POP
server to extended System Control Facility (XSCF) is
supported in PRIMEPOWER250/450.

PG22891

The prohibition to invalidate Name Server Administration
when some parameters is specified with Hostname on the
extended System Control Facility (XSCF) Basic Configuration
Administration in PRIMEPOWER250/450.

PG22892

Improvement of the Mail Administration menu of the extended System Control Facility (XSCF) menu in
PRIMEPOWER250/450.

PG22893

Improvement of the error handling process for invalid character inputs on the extended System Control Facility (XSCF) Administration Menus in PRIMEPOWER250/450.

PG22894

The extended System Control Facility (XSCF) SSH function is
supported in PRIMEPOWER250/450.

PG22764

Enhancement of the CPU offline function to display the retry out message in PRIMEPOWER250/450.

PG23097

When the HCP not supported is registered, an invalid message
is displayed in PRIMEPOWER250/450.

PG23082

Enhancement of the error message monitoring for the PCI Hot
Plug Controller in PRIMEPOWER250/450.

PG23101

The function of the log collection might stop when CPU trouble
happens frequently in PRIMEPOWER250/450.

PG23213

Enhancement of the judgment logic of Standard Console port
selection on the extended System Control Facility (XSCF)
Console Administration menu in PRIMEPOWER250/450.

PG22961

When network products other than TCP/IP are being used,
hardware configuration information may be unable to be
recognized correctly in PRIMEPOWER250/450.

PG21637

When the error of BLASTBAND is detected, an unnecessary message might be displayed on a standard console in
PRIMEPOWER250/450.

PG21638

The save of log data might fail in PRIMEPOWER250/450.

PG22168

In PRIMEPOWER250/450, the empty file of a meaningless
name is generated, and updated every 6 hours.

PG22228

After many hardware error logs occur, hardware error logs
might not be collected in PRIMEPOWER250/450.

PG22243

The hardware configuration information might not be
recognized when a network product other than TCP/IP is
used in PRIMEPOWER250/450.

PG20369

Enhancement of the CPU offline function.

PG20370

Performance improvement in trace log collection library.

PG20364

The file to be saved by the savelogs command might be doubly
saved.

PG20366

Enhancement of function to detect replacement of unit by check on serial number.

PG20367

Enhancement of function which synchronizes with state of unit
of XSCF.

PG20368

The DC power supply models of PRIMEPOWER250/450 are
supported.

PG20373

When the error of the I/O device is informed, SCSI-ID of the
unit might be displayed by the hexadecimal.

PG20349

Display order of the selection item is wrong in "Hardware Error Log" menu.

PG20350

Enhancement of function to display log in order of time-
stamped record in "Hardware error Log" menu.

PG20351

Enhancement of function to refer to detailed log in "Hardware
Error Log" menu.

PG20381

Improvement of the firmware update menu.

PG20380

Improvement of the condition of HCP update.

PG20378

Improvement of the way of collection error (details) log.

PG20384

Enhancement of command to update configuration information
at hot swap.

PG20385

Enhancement of the Hardware configuration display function.

PG20498

The command to display the serial number of the server is
supported.

PG20511

Improvement of the hardware configuration information
update processing after the OS is booted.

PG20436

Information is not stored in madmtrace into detail log directory

PG20492

Enhancement of the function of the error notification control

PG20464

The error report of the disk is not correctly reported.

PG20512

Improvement of the order and the item names in the Machine
Administration menu.

PG20513

Enhancement of the function to operate the CHECK-LED of
the server.

PG20514

Enhancement of the notification test function.

PG20516

Enhancement of the function to collect CPU SK-history log.

PG20518

Enhancement of the warning message at the prevention
replacement.

PG20544

The usage message of setfandly command is wrong.

PG20542

Enhancement of Automatic Power-on Prohibition Mode after
FPO(Forced Power Off).

PG20617

The CPU SK-history logs are not collected at the shutdown.

PG20579

Improvement of function: When transfer of hardware error log
information from XSCF was interrupted due to any reason, such as panic of system, Enhanced Support Facility will repair
interrupted information during next starting up and store it to
normal logging space.

PG20608

An unnecessary detailed log might be displayed in the
Hardware Error Log menu.

PG20610

The input of a specific character might not be accepted in the
Hardware error Log menu.

PG20589

The improvement of the extended System Control Facility
(XSCF) Administration menu.

PG20629

The error message of the scfsnmp command is wrong.

PG20618

Can not read the output from child processes.

PG20680

Correction of message of "Read-only console" in the extended
System control Facility (XSCF) Administration menu.

PG20681

When informing of the error detected by XSCF, the function
of the error notification control does not work correctly.

PG20682

Enhancement of function to control syslog output about the
notification of the error which XSCF detected.

PG20709

The validity check on the address of the SNMP server might
be wrong.

PG20710

The same address setting check of the SMTP server might be
wrong.

PG20718

Enhancement of function of PHP in configuration information
display.

PG20719

Information of CPU might be wrong in configuration
information display.

PG20721

When illegal status is read, the hrdconf command dumps the core.

PG20722

Improvement of message about the function of the error
notification control.

PG20909

Improvement of message when factor is CPU in Power Log menu.

PG20917

Confirmation article of Notification Test is added to the help
message.

PG20818

Hardware Error Log might be terminated by program error.

PG20881

The hardware error log might not be stored.

PG20984

Explanation of unit is added to the help message.

PG20986

The status of Machine Administration and XSCF might not be
synchronized about PSU.

PG20987

In the PRIMEPOWER250 pedestal type, the number of FAN
displayed by the hot swap guide is wrong.

PG20809

Help-documents correction about SNMP setup of SCF
configuration menu.

PG20826

Internal command error message correction about XSCF
configuration menu.

PG20956

Help-documents and message correction about XSCF
configuration menu.

PG21084

In the error notification, the unit number might be wrong.

PG21041

The error notification of an environmental error is not
controlled.

PG21042

The notification to the REMCS center might be wrong.

PG21181

The processing of the menu might not stop when the RCI
reconfiguring fails.

PG19639

When configuration information is displayed with the server
which connects the SDU device, the same SDU device might
be displayed two times

PG19669

The error of exchanged parts cannot be detected at the hot
swapping in "Management of Hardware Error Event" menu.

PG19681

"Error detection stop" command is not reissued when you type
"ok" after the count passes of 300 seconds in the "Power Supply
Unit of Main Cabinet" menu of the Hot Swapping menu.

PG19682

"FEPFAN status" is displayed in the index of the state column in the "Power Supply Unit of Expansion Cabinet" menu.

PG19683

The message in the Hot Swapping menu might cause the mislead that the input of Cancel is recommended than the input of OK.

PG19570

The prevention management of miss-configuration of the
Standard Console.

PG19672

Name change of "Host Name" setup menu.

PG19676

Deletion of the function of SNMP access mode selection.

PG19698

In the Remote Customer Support System (REMCS) Setup
menu, the device serial is displayed by the decimal number.

PG19774

The error notification mail and the syslog report is wrong.

PG19809

The state of the list after the hot swapping might be different
From the state of the hardware configuration display.

PG19805

The help message of the machine Administration menu is
incorrect.

PG19808

The help message of the Power System Administration menu
is incorrect.

PG19807

The procedure when unmounted parts are section is not
described at the help message of " Power Supply Unit of Main
Cabinet" menu in the "Hot Swapping Guide".

PG19800

The longevity of the fan and the battery which the Machine
Administration monitors might not be notified.

PG19797

In configuration information, detailed information of tape drive
might not be display.

PG19796

Updating of configuration information might be slow.

PG19804

The user account registered by the extended System Control
Facility (XSCF) Administration menu cannot log in XSCF.

PG19680

When the addonflush command is executed, the daemon of the
Machine Administration does not work correctly.

PG19811

The help message of the Management of Hardware Error
Event menu is incorrect.

PG19813

The mirroring disk of the Synfinity Disk might not be correctly
displayed by configuration information.

PG19783

The function to specify and display the XSCF shell access key
word are added.

PG19784

The number of SMTP server and Name server of XSCF
Administration menu is changed.

PG19778

The help message of the Enable mail Report (and Setup) menu
is incorrect.

PG19779

An input error is taken again by the re-input after the input
error by XSCF user configuration.

PG19780

The user name which is the sub-string of the existent user name can't be added by XSCF user configuration menu.

PG19781

A screen transition is incorrect on the setup menu of the SNMP
trap of XSCF.

PG19818

A screen transition is incorrect on the setup menu of the Port
Access of XSCF.

PG19819

Previously set "Completion time" does not recovered when "q"
is inputted in "Specification of Time" of "Hardware Error Log"
menu.

PG19867

In the Management of Hardware Error Event menu, the fan of
SDU driver cannot be retrieved by specifying types of parts.

PG19910

When Restoring Hardware Monitoring Information is executed
the function of the SIRMS might not work correctly.

PG18615

All users might be able to write the file made by the Machine
Administration.

PG19289

The spelling of "Vendor" is wrong in the hrdconf command.

PG19295

Some commands to have permitted a general user to use do not
work by general user authority.

PG19302

The search function of the Management of Hardware Error
Event menu does not work correctly.

PG19303

The check on the input character does not work correctly in the
Host Name Configuration of extended System Control Facility
(XSCF) Administration menu.

PG19304

The longevity notification mail is not transmitted.

PG19305

The setpwrmode command displays the setting which are not
supported in PRIMEPOWER250/450.

PG19308

The message in the Hardware Error Log menu is wrong.

PG19311

The Setting Monitoring Notification Information menu does not work.

PG19319

When information on an abnormality of battery is reset, the
longevity time is also reset.

PG19322

The error notification mail is not sent to maintenance
personnel.

PG19334

The SMTP server setting is not work correctly in the extended
System Control Facility (XSCF) Administration menu.

PG19335

The HCP Administration menu changes the SCF bank even if
the SCF firmware is not updated.

PG19353

The SCF firmware version is not displayed correctly in the
Hardware Configuration Display menu.

PG19354

The CPU information is not displayed correctly in the hrdconf
command.

PG19356

The positional information which is informed to XSCF was wrong.

PG19423

The mail address and the memo might not be able to input
even the regulated number of characters in the Setting
Monitoring Notification Information menu.

PG19425

The error notification of the RCI node is not displayed
correctly.

PG19426

The status of the FAN and the PSU might not be correctly
displayed in the Hot Swapping Guide menu.

PG19427

The set object device is not displayed in the Setting the
External Equipment Wait Time menu.

PG19428

The setwarmup command cannot be executed.

PG19429

When longevity of the disk and the tape is notified, the error
Unit might not be correctly informed of.

PG19430

The Fault LED is not displayed in the configuration
information.

PG19431

When two or more PCI cards with the same driver name and
without instance number are installed, the configuration
information is not normally displayed.

PG19432

The menu might loop infinitely in the extended System
Control Facility (XSCF) Administration menu.

PG19294

The error was set both of the PCI card and the hddv device
when the hddv device was defected.

PG19477

When the battery is registered, the longevity is not reflected in
configuration information.

PG19440

The configuration change processing loops infinitely when the
madmdb file is broken.

PG19444

When the correctable error occurred at the UPA bus, the report
message might be different from the manual.

PG19429

At the error notification or the longevity notification of the
I/O device, the indicated part is not occasionally informed of by
a correct format.

PG19560

The error mark set in the past is overwritten at the error
notification of the I/O device.

PG19561

The log of the error notification of Synfinity Disk cannot be
detected by using the filtering functions of parts in Hardware
Error Log menu and Management of Hardware Error Event
menu.

PG19562

The content of the message is improper in the Management of
Hardware Error Event menu.

PG19448

A part of temporary file used in the machine administration might not be erased.

PG19442

The message notified from SCF were not stored in the machine
administration monitoring log.

PG19473

The error log list might be displayed in the Hardware Error
Log menu instead of detailed information.

PG19572

The item of the subcommand not supported is displayed in
usage of setrci.

PG19571

There is a misprint in usage of setexwait.

PG19573

The screen update is too fast after the left count becomes 0
seconds at the hot swapping of FAN/PSU in the Main Cabinet.

PG19489

When the log of the firmware update history display overflows
from one screen, the log cannot be displayed.

PG19529

When the Auto-disconnect function of XSCF is registered, the
connection to SCF LAN temporarily becomes interrupted.

PG19528

The unit of the character is improper in the XSCF
Administration menu.

PG19527

When the host name is initialized in the Host Name
Configuration menu of XSCF Administration, it becomes "-"

PG19509

After the input is mistaken, the re-input is not correctly
checked in the Host Name Configuration menu of XSCF
Administration.

PG19570

A standard console cannot be used when switching from the
serial port to LAN port without correctly setting SCF LAN
in the Select Standard Console menu of XSCF Administration.

PG19565

When some PCI-CARDs of which the component-name
property is different exist under U2P, Hardware Configuration
is not correctly displayed.

PG19566

The node name of degenerated CPU is not displayed by the
hrdconf command.

PG19567

The cash size of CPU might not be correctly displayed in the
hardware configuration information.

PG19568

The error mark might not be added to the degenerated memory
in the hardware configuration information.

PG19950

The function to extract the log file was supported.

PG20387

Enhancement of function to display error message in the
inst2comp command.

PG18684

Disk firmware updating fails when the Ultra320 SCSI card is
used.

PG19575

PW028SY1 was supported.

PG21929

On PRIMEPOWER800/1000/2000, GP7000F Model1000/2000,
the notification processing of the CPU abnormality might be
delayed.

P805293

On PRIMEPOWER800/1000/2000, GP7000F Model1000/2000,
the empty file of a meaningless name is generated, and
updated every 6 hours

P805737

After a certain period passes, the evsndd daemon dumps core
or loops infinitely in GP7000F Models 1000/2000,
PRIMEPOWER800/1000/2000.

PG24788

PRIMEPOWER650/850 DC power input model supported.

PG24934

The normal CPU is offlined on PRIMEPOWER650/850 with
SPARC64-V model.

PG24941

If the FAN unit failure occurred, Set wrong mark to FEP on
PRIMEPOWER650/850.

PG24014

Check CPU offline function at system boot and each 1hour added.

PG24015

Add CPU offline fail message output.

PG24016

The memory correctable error message level changed
WARNING to ALARM.

PG24017

The HPC3130 configuration display is wrong on
PRIMEPOWER2500/HPC2500.

PG24018

The SB(System Board) interleave information is wrong on
PRIMEPOWER2500/HPC2500.

PG23831

CoD(Capacity on Demand) illegal use message not reported to
SMC(System Management Console)

PG22907

In Cluster environment, When network products other than
TCP/IP are being used, hardware configuration information
may be unable to be recognized correctly.

PG22622

The Console message "_DNFAN not found in
/var/opt/FJSVmadm/etc/madmdb" displayed at system boot.

PG22595

DN42 file unit supported.

PG22594

Even if it makes a System Board configuration change by
DR(Dynamic Reconfiguration), the old configuration is
displayed by machine administration hardware configuration
display menu.

PG22295

After a certain period passes, the evsndd daemon dumps core
or loops infinitely.

PG22365

The empty file of a meaningless name is generated, and
updated every 6 hours.

PG22001

When network products other than TCP/IP are being used,
hardware configuration information may be unable to be
recognized correctly,

PG21543

The CPU offline succeed message displayed when offline fail.

PG21137

The environment save/restore fail in Live Upgrade.

PG20944

The command to display the serial number of the server is
supported.

PG20945

Enhancement of the function of the error notification control.

PG20946

Enhancement of the function of PHP in configuration
information display.

PG20947

Information of CPU might be wrong in configuration
information display.

PG20950

Enhancement of command to update configuration
information at hot swap.

PG20195

Cannot connect to stand-by SMC(System Management
Console) on SMC redundant system.

PG20048

The Hardware Configuration display menu may be fail on
PRIMEPOWER2500

PG20047

The cpucomponent command takes long time.

PG19848

The hrdconf command takes long time.

PG19349

The "Setting Monitoring Notification Information" sub-menu in
The Hardware Monitoring menu may not open.

PG19235

At the time of the unusual detection with unknown Failure
Unit, Failure Unit is displayed as detection CPU.

PG19234

The display of PCIBOX may not be performed in the hardware
configuration display of PRIMEPOWER650/850.

PG18254

The setmadmdb command dumps core, when unit entry deleted
from Machine Administration database.

PG18040

The SPARC64-V peculiar function (kernel message, CPU type
code addition , CPU offline) supported.

PG22597

In GP7000F Model200/200R/400/400R/400A/600/600R, the
getmodelcode command terminates abnormally, and the model
might not be judged correctly.

PG22380

In PRIMEPOWER1/100/200/400/600,GP7000F
Model200/200R/400/400R/400A/600/600R, FUJITSU S series
and GP7000S series, the empty file of a meaningless name is
generated, and updated every 6 hours.

Remote Support

PG21780

Periodical connection time might not be displayed in the
REMCS Environment menu under english environment.

PG20806

Point-to-Point(VPN) connection is supported.

PG20807

Enhancement of the function to do Periodical Connection every
day is supported.

PG20808

Save and load of registration data is supported.

PG21054

Enhancement of the menu message.

PG21055

Enhancement of the help message.

PG21080

"Update" is appended to menu which is displayed after load of
registration data.

PG21164

Core file is generated after load of registration data.

PG17213

Internet connection (Mail Only) and POP before SMTP are
supported. Error message is enhanced.

PG19583

The redundant configuration of System Management Console
is not supported.

PG20093

The frequency of the CPU of PRIMEPOWER200/400 supports
the display of system board of 800MHz type on the Vconfig
screen of WebSysAdmin(WSA).

PG20492

Enhancement of the function of the error notification control.

PG20658

The multithread unsafe functions are used.

PG21773

New feature is appended for REMCS report via XSCF.

PG21842

Address and building for the machine are appended to
registration data.

PG22267

When 'q' is selected, next menu displayed is depending on
connection type

PG22268

Information for user authentication of SMTP is not saved at
creating upload-file.

PG22284

Message improvement. When the setting is invalid, should not
ask to 'change' it.

PG22314

Some items are written to registration file as #%NUL%# if
they are invalid.

PG22520

Mail Address is not checked whether it contains '@' in the
middle.

PG22601

Space character is not accepted for the password.

PG23135

Next registration fails when site-server is changed twice.

PG22112

Difference of software configuration is not reported until next
power-on.

PG21767

Connection time is not displayed when periodical connection is
everyday.

PG21300

Sender E-mail Address is broken.

PG20396

Error message are appended for save and load of registration
data.

PG20427

CPU's type, serial number and version are appended to the
machine information.

PG20468

Core file is generated when broken registration data (Length is
zero) is loaded.

PG20636

At loading of registration data, data area remains allocated.

PG20637

Internal area is broken when length of the name of registration
data file is over 64.

PG20638

Ask (y,n,q) when the registration data can be loaded.

PG20639

Improvement of help in the menu of selection of Connection
Type.

PG20672

Can not read environment data when connection type was
Point-to-Point Connection(VPN).

PG20937

New feature is appended for everyday periodical connection.

PG20940

New feature is appended for save and load of registration data.

PG20942

New feature is appended for connection via VPN router.

PG19907

PCI Component Name in the machine information is null
string.

PG19914

CPU Mask in the machine information is zero.

PG18350

Password for user authentication of SMTP is displayed.

PG19547

Temporary file is left after package remove.

PG22200

The location information of the PCI card in the hardware
configuration information sent to the REMCS Center is worng.

PG21819

Connection time is not displayed when periodical connection is
everyday.

PG21301

The contents of registration data may break.

PG19219

The host name of the host name displayed column of a REMCS
center web may not be displayed correctly.

PG20632

New feature is appended for everyday periodical connection.

PG20633

New feature is appended for save and load of registration data.

PG20634

New feature is appended for connection via VPN router.

PG18792

The country name in the customer information may be
displayed with 99 at Registration.

PG18793

There is a security vulnerability of the POP password saving at
the Registration.

PG18827

The multithread unsafe functions are used.

PG18829

Correction of the CPU type code within the hardware
configuration information sending to the REMCS Center.

PG20053

Customer information and Environmental setting information
carrying -about function and P-P(VPN) connection are not
supported.

PG21258

When the division mail is transmitted with two or more devices at the same time, E-mail might not be able to be received normally at the center.

PG16899

Because protocol to which RFC does not conform is used,
mail might not be able to be transmitted correctly.

Auto Power Control System

PG21595

A Automatic power control on PRIMEPOWER1500/2500
systems stopped by the performance problem of SCF.

Server Default
Configuration

PG19738

SCF might be not informed of system panic in the event of request switch or dump request from the System Console.

Auto Dump
Analyze Tool

PG21049

The following message might be displayed on the System Console during booting after panic.
"scrash: ioctl TIOCREMOTE failed"

Reliability Driver

PG23541

soft interrupt stops, which will stop the console output and
other processes later.

PG20212

output of console stops and shutdown will be hung.

PG20231

synchronous communication via standard serial port fails.

PG24943

If a system board is connected by Dynamic Reconfiguration,
panic may occur.

PG25851

Disconnetion of the system board by the Dynamic
Reconfiguration may fail.

PG25846

If a system board is connected by Dynamic Reconfiguration,
panic may occur.

PG25852

Disconnetion of the system board by the Dynamic
Reconfiguration may fail.

HCP

PG23203

Patch data corresponding to HCP0501

2.3

Machine Administration

PG13550

The contents of Setting Monitoring Notification Information will be reflected in a Setting Battery Life Notification

PG13551

The add-on detection error message of hddv may be missing

PG13554

The Status of ETHERNET#0 on SCFA#0 and ETHERNET#0 on SCFA#1 indicate ALARM when ETHERNET#0 on SCFA#0 error detected

PG13556

The setexrdy command fails when external power supply control device (RCIC) in INACTIVE (power off) state.

PG13557

The list of RCI devices not updated after RCI network configuration or initial-configuration

PG13558

The Domain creation is not permitted from WebSysAdmin

PG13559

The PCIBOX connected SB#1 not displayed by hrdconf command

PG13560

The notation methods differ [ the check message of FirmUpdate ] in Japanese and English

PG13573

On PRIMEPOWER800/1000/2000, GP7000F Model1000/2000, when the partition of the multiprocessor environment boots OS, the evsndd daemon might hangup. Therefore, the boot sequence might stop.

PG13991

The RCI address in error message of another node panic is always 0

PG14128

Monitoring the external file unit(PW007FL2/PW007FL2U) was
supported.

PG14705

The console display message is not compatible to other PRIMEPOWER series.

PG14793

Cannot get System Console Software REMCS status from Enhanced Support Facility Machine Administration

PG14794

The Disk firmware update by remote host failed

PG14795

It guarded so that a prtpwrlog command could be executed only by the model which can operate.

PG14796

The getmodelcode command supports all PRIMEPOWER models

PG14797

The hardware error log and report log save for 1 entry fails

PG14870

The error notification by mail does not work from System Console in the model with a System Console.

PG15042

The abnormal temperature monitoring function was supported on
PRIMEPOWER1/100/200/400/600,GP7000F Model200/200R/400/400R/400A/600/600R.

PG15048

System boot stop by Machine Administration RC command not return

PG15170

The additional kernel message support

PG15171

The DDC(DC-DC Converter) type displays at hardware configuration menu and failure messages

PG15436

The sfdsk(mphd) message of the failure unit wasn't reported, the wrong driver message of the failure unit reported when the sfdsk(mphd) message and the driver message reported at the same time.

PG15437

When the error message of the disk driver is added and monitored, the disk under the control of SynfinityDisk is monitored.

PG15685

The all abnormality may not be reported normally when more than one monitoring of abnormality occurred in a short time.

PG15766

Fan unit of main cabinet of another host of RCI-connected is observed by monitoring of fan unit of expansion cabinet.

PG15816

The getmodelcode command supports new PRIMEPOWER models

PG15817

It is not connectable with the standby side in the System Management Console redundantly setup

PG15818

The CPU frequency display value of hardware configuration display menu is not correctly

PG15835

When the error message of the disk driver is added and monitored, the disk under the control of SynfinityDisk is monitored.

PG15856

On PRIMEPOWER800/1000/2000, GP7000F Model1000/2000, The redundant SMC function is supported.

PG17315

The sfdsk(mphd) message of the failure unit wasn't reported, the wrong driver message of the failure unit reported when the sfdsk(mphd) message and the driver message reported at the same time.

PG17316

On PRIMEPOWER800/1000/2000, GP7000F Model1000/2000, information is sent only to Service SMC in the Hot Spare SMC.

PG17319

On PRIMEPOWER800/1000/2000, GP7000F Model1000/2000, when the command by which SMC is set is executed, it executes the shareall command.

PG17324

On PRIMEPOWER800/1000/2000, GP7000F Model1000/2000, the hrdconf command might display wrong information on a disk.

Remote Support

PG13058

Software configuration information may not be sent to REMCS center.

PG13315

The Periodical Connection may not be made.

PG13317

An error code may not be displayed on the error message at the failing time of connection check.

PG13318

Statistics information may not be notified.

PG13319

The error output of a "cat" command may be displayed on the console.

PG13932

The registration may be failed and a core file is created at the root directory.

PG14677

The REMCS reported message is not compatible to other PRIMEPOWER series.

PG15554

Can not registration from Management Server.

PG15767

The mistake might be found in information on next Periodical Connection Schedule of Periodical Connection event information to the REMCS Center.

PG15768

The mistake might be found in information on code of customer information to the REMCS Center.

PG18593

The mistake might be found in information on code of customer information to the REMCS Center.

Crash Dump Assistant

P804853

Access is impossible from a client node to a share file system after

Execution of the fjdmpadm and scslset commands.

CPU Patrol
Diagnosis

PG13776

An unnecessary message may be displayed when the LANG environment variable is "ja" on Solaris 9 OS.

2.1

Web-Based Admin View / WWW Server for Admin View

PG10309

Menu which cannot be selected exists even if user logins as wvroot group.

PG10310

Command execution processing may stop in JavaVM.

PG10311

Phraseologies different from other screen on Environment setup screen is corrected.

PG12175

When an illegal request was sent while connecting with WWW Server for Admin View, the content of the displayed error message is wrong.

*SCF driver

PG10648

When abnormality such as FAN/FEP occurs with the external unit such as FDE connected on RCI, neither the part name nor the part number are output to *SCF driver's WARNING message.

PG11623

PG11723

Scfctlbrk command support.

SunVTS,FJVTS

PG12533

When there is a cpu which status is "no-intr", the FJVTS will be core dumped by invoking it.

Machine Administration

PG12314

The machine administration hardware configuration display of PCI disappears PP028GE1 or PW008QE1 at PP028GE1 and PW008QE1 both installed system.

PG12316

The Machine Administration error report message might not point out the failure unit.

Remote Support

PG11806

A software event may not be sent to REMCS center.

License Manager

P803908

When the name service has stopped, the license manager is started or stopped slowly.

Reliability Driver

PG12200

PG12694

The drc command stops on the connection script FJSVse and doesn't return.

P804182

"WARNING: interrupt level 4 not serviced" is displayed.

2.0

*SCF driver

P803604

When X1141A card is installed, and "drcstat -device" is executed, the device of hme and ge might be displayed duplicatede.

Machine Administration

PG10380

The machine administration misunderstands FAN/FEP mounting data on PRIMEPOWER650 and 850.

PG10382

The Hardware error information is not set at FAN/FEP/PCIBOX on PRIMEPOWER650 and 850.

PG10383

Error indication of PCIBOX displays another PCIBOX on PRIMEPOWER850.

PG10384

Error indication of PCIBOX can not be disappeared after it maintained on PRIMEPOWER650 and 850.

PG10405

User who is not belonging to the root group can't display "Hardware Configuration" in the CUI menu.

PG10580

Error indication of FAN/FEP can not be disappeared after it maintained on PRIMEPOWER650 and 850.

P803654

The herdconf command may display incorrect hardware composition after changing the system configuration by Dynamic Reconfiguration.

Auto Power Control System

PG09849

Warning message three minutes before the shutdown may not be displayed.

1.8

*SCF driver

P803424

Even if a UPS is reconnected after momentary power failure,it is likely to be shutdown.

SunVTS,
FJVTS

PG07857

When the fjswutest is executed, a core dump may be generated.

Machine Administration

PG06692

The hrdconf command dumps core when the system has many disk instances.

PG06714

The hrdconf command dumps core when the system has many disk instances.

PG06724

When an abnormal report to the REMCS center happens frequently,
a report omission might be generated.

PG06904

On PRIMEPOWER1/100/200/400/600 and GP7000F Models 200/200R/400/400R/400A/600/600R, a message that is not the watch object is observed.

PG07158

The Machine Administration might generate an incorrect message error , when two or more messages occur at the same time.

PG07201

A fibre channel card error might not be generated.

PG07202

The Machine Administration might generate an incorrect error message, when two or more messages occurred at the same time.

PG07214

A fibre channel card error might not be generated.

PG07540

When abnormality occurs in the main Cabinet FAN, an unnecessary message of "test: argument expected" is displayed on the console.

PG07653

The hrdconf command displays "GP7000F" as the series name for PRIMEPOWER800/1000/2000 when the product ID starts with "PW".

PG08308

The Machine Administration may inform of a panic though kernel does not panic.

PG07909, PG08309

The Machine Administration displays a normal disk as in error, when the RAID controller of the other path fails.

Remote Support

PG06589

The menu screen of Software Investigation Information Collection is corrupted.

PG06721

A mistake is found in the abnormal report format sent to the REMCS center.

PG06723

HW configuration data to which the CD-ROM configuration is changed when the disk configuration is changed might be notified to the REMCS center.

PG06727

After setting of REMCS environment, an Http Proxy password may become invalid..

PG06772

When Remote Setup menu is executed in an English environment, a mistake is found in the displayed message.

PG06917

Temporary file sometimes found in root directory when connection confirming failed.

PG07046

Periodical Connection Time is not correctly set when setting or changing Periodical Connection Time on the change day for summer time/daylight saving.

PG07536

A mistake might be found in information on FEP or FAN of HW configuration data notified to the REMCS center when a FEP or FAN abnormality occurs.

PG07537

A mistake might be found in information on the memory of HW configuration data notified to the REMCS center.

PG07538

A mistake might be found in information on the CPU of HW configuration data notified to the REMCS center.

PG07539

Information on DISK of HW configuration data notified to the REMCS center might be missed.

System Data Output Tool

P803159

Information output by prtdiag command might not be collected.

Reliability Driver

PG05363

In a system in which the console path is made redundant, if a change occurs due to path abnormalities , the console display under reboot will not be carried out.

1.7.1

Machine Administration

PG05054

An unnecessary message might be displayed on the console after the system panics.

PG05154

The part of the message that indicates possible error locations (SCSI ID) may be incorrect in the tape cleaning notification.

PG05163, PG05250

When you terminate the terminal or log out while running the Machine Administration menu, the menu loops in the background for awhile, in some cases, a core dump might be generated.

PG05164, PG05255

When an error message is detected continuously on the same kind of I/O devices, the Machine Administration may not identify the unit correctly.

PG05165

When system time is changed by the date command, the evsndd cannot communicate with a System Management Console normally.

PG05166

When the evsndd is started multiple times, a core dump is generated.

PG05056

Moving a tag on the Machine Administration GUI menu may cause the GUI menu to enter an abnormal state.

PG05254, PG05641, PG05646

The Machine Administration GUI menu might terminate abnormally when characters such as "!" , "(", and "=" are input.

PG05642

Typographical errors may not be pointed out even if a nonexistent character string is input on the Machine Administration CUI menu.

PG05643

The evsndd might not inform the system administrator of its status by mail when cutting communication with a System Management Console.

Remote Support

PG05490

An error message may not be reported to Fujitsu Support Center even in the case of a system panic.

1.7

Machine Administration

PG04395

An unnecessary message might be displayed on the console.

1.6

*SCF Driver

PG00679

*SCF driver does not control twenty four or more RCI devices. In this case, the rciinfo command indicates "0" to each subsequent RCI device.

SunVTS,
FJVTS

PG02477

The fjvts command cannot be executed on Enhanced Support Facility 1.5 or 1.6 in the following conditions when:

  • The system is Solaris 7 OS or later.
  • Only 32-bit kernel has been installed.

Machine Administration

PG02568

The error message displayed on the console does not have a device name when device degradation occurs during system initialization.

PG02570

The Machine Administration does not detect a single-bit memory error on PRIMEPOWER1.

PG02567

When using Saving the Log Data, the message "Hit return key" is displayed twice.

PG02596

The prtpwrlog command returns the value other than "0" even if the command has completed successfully with the -x option.

PG02374

When using Saving the Log Data, the message "The file has already exist " is displayed twice if the file name already existed.

PG02435

When using Saving the Log Data, specifying a file name with a relative path name causes to save the file is relative to the root.

PG02276

On PRIMEPOWER and GP7000F Models 200R/400R/400A, the abnormal state of the CPU degradation displayed in the Hardware Configuration of Machine Administration is not reset even though the system is rebooted.

PG01956, PG02484

The guidance "To specify more than one, use a comma to delimit the number such as 1,2." displayed on the menu is incorrect when using Saving the Log Data.

PG01957, PG02487

An unreadable message is displayed on the Disk Firmware Administrator Menu when an error occurs.

PG02274, PG02485

Even though an incorrect parameter is input, the subsequent steps request you to input the file name you want to save when using Saving the Log Data.

PG01863, PG01857

The hardware error is not notified even if it occurs on the array disk unit (GR730 or GR740).

PG02280

Some of *SCF error codes may not be recorded in the Power Error Log.

PG02130, P802357

Depending on the timing of cutting and reconnecting, the "DOWN" state may be displayed on the host selection window of GUI even if the node is normal.

PG01953

The items and the contents that indicate the battery status and life have reversed on the Adding Battery Life Information of GUI.

1.5

Machine Administration

PG00766

The menu or the command usage represented on the display is incorrect.

PG00767, PG00771

Machine Administration does not detect any error message related to the new SCSI adapter device(LVD).

PG00768

The RCI address may be set to the initial value on the host selection window of Machine Administration even if it has been set.

PG00769

Letters for "ErrorCode:0x8046000" are not displayed on the *SCF error log display of Machine Administration.

PG00924, PG00989

The hardware error is not notified immediately even if the kernel and driver error messages are detected. In the event of shutting down the system, the kernel and driver error messages may be lost.

PG00933
PG01000

In the monitoring of disk, tape unit, fan, power supply unit, and battery life, all of their information may not be notified even if two or more units are under the report conditions.

PG00851, PG00850

The degradation of the array disk unit (GR720) components is not reported.

PG00951, PG01248

The top menu does not appear when "t" is selected on the Disk Firmware Administrator Menu of Machine Administration.

PG00999, PG00925

Some configuration data is not restored when Enhanced Support Facility is reinstalled.

PG01029, PG00977

The date based searches are not performed correctly when date condition is specified two or more times on the CUI Log Data Menu of Machine Administration.

PG01088, PG00976

The part of the message that indicates possible error locations may be incorrect when the WAN adapter error occurs.

PG01114, PG00975

The setpwrmode command confuses EPCREIPL and POFFRCV when displaying and setting EPCREIPL.

PG00766, PG01271

Wrong message is displayed on the Machine Administration menu and command usage.

PG01234, PG01272

The syslogd error message may be displayed when shutting down the system.

PG01236, PG01273

The host name may not be displayed on the Host Selection window of the Machine Administration GUI menu after updating Enhanced Support Facility.

PG01008

The function for setting up IPL signal of RCIC that is not supported on the unit can be available by using the Machine Administration menu and commands.

PG01025

Illegal characters may be displayed on the power log display of Machine Administration.

PG01096

"Saving the log Data" on the Machine Administration CUI menu becomes abnormal.

PG01188

The following file may remain illegally even if Machine Administration has been uninstalled./opt/FJSVmadm/lib/regist.bin.bak

PG01191

The part of the message that indicates possible error locations may be incorrect when a SynfinityDisk error is detected.

PG01192

The power supply unit fan (FEPFAN) that is monitored by the Machine Administration is displayed with a maximum delay of 24 hours.

PG01220

Reset of tape unit monitoring information and setting of tape unit monitoring notification cannot be made on the Machine Administration menu.

PG01263

The hot-swapping of FAN#14 cannot be made on PRIMEPOWER400.

P802362

The evsndd daemon may output a core dump if the communication with System Management Console failed on PRIMEPOWER800/1000/2000 and GP7000F Models 1000/2000.

P802347

The shutdown command may be ineffective if the communication with System Management Console failed on PRIMEPOWER800/1000/2000 and GP7000F Models 1000/2000.

PG01247

The power supply linkage mode that is not supported on PRIMEPOWER800/1000/2000 and GP7000F Models 1000/2000 can be set.

System Data Output Tool

PG00799

The fjsnap command may be executed while it is being executed.

License Manager

P802190

FLEXlm license daemon sometimes fails to start when the node name takeover of 1:1 standby is set with SynfinityCluster system.

1.4

*SCF Driver

PE14351

*SCF driver shuts down a system when a permanent error of *SCF hardware/firmware occurs.

SunVTS,
FJVTS

PE14523

The following error related to the semaphore occurs while the fjbcdrtest or fjwpcdtest commands is running for a long period of time.
SUNWvts.fjwpcdtest.function_test.8009 12/28/99 01:53:32 fjwpcdtest pc2c-00 FATAL:
"semop failed. Resource temporarily unavailable"

Web-Based Admin View / WWW Server for Admin View

PG00532

The system status may become abnormal or the correct data for investigation may not be collected in the following conditions when:
The system is Solaris 2.6 OS, Solaris 7 OS, or Solaris 8 OS.
Enhanced Support Facility 1.4 has been installed.
The management server is accessed from the clients to use Web-Based Admin View.

Machine Administration

PE14273

Machine Administration sometimes continues the increasing of management log files infinitely.

PE14484

The actual system condition is not displayed correctly on the power log display.

PE14534

The hard disk hot-swapping may not be made.

PE14608

In the hardware monitoring information notification setting, the display of the notification destination has reversed in the English mode.

PG00302

Because the tape cleaning monitoring of Machine Administration conflicts with the tape device opening of another application during system start-up, the application may terminate abnormally.

PG00303

The errors may be displayed on the console once every 24 hours when a RAID device is connected.

PG00304

The serial number of the disk is not displayed in the hardware configuration display.

PG00305

There is no message on the memory information display menu even when the memory error occurs.

PG00320

FAN#12 or FAN#13 seem to not be mounted on GP7000F Models 400A and 400R in the configuration information notified the REMCS center.

PG00332

On GP7000F Models 200, 200R, 400, 400R, 400A, 600, and 600R, the REMCS agent menu terminates abnormally in the following conditions when:

  • The locale is set to C.
  • Set the MODE switch to MANUAL.
  • Select the maintenance end.

PG00370

The hardware error is not notified even if it occurs on the hddv disk connected with the fiber channel.

PG00410

In the fan life monitoring, FEPFAN which does not exist on GP7000F Model 200 is added.

PG00412

The Power Recovery Mode setting by the setups command is not validated.

PG00419

Unusual behavior may be caused by inputting a special character string in the REMCS agent menu.

PG00420

The message of the report mail by which the error is detected by SynfinityDisk becomes abnormal.

PG00485

The Machine Administration menu terminates abnormally when a character string containing a space character is input into a field on the top menu.

PG00487

Battery or fan information can be registered by the setbattlife or setfanlife commands even if the identification number is not specified.

PG00488

The setpwrmode command fails to display the state of EPCREIPL.

P801826

When the prtmsglog command is executed, a core dump may be generated.

Auto Power Control System

P801928

When the environment variable "LC_ALL" or "LC_MESSAGES" is set, Auto Power Control System sometimes fails to set the shutdown schedule.

P801941

When cron daemon has been stopped, Auto Power Control System respons no error while you set the schedule.

System Data Output Tool

PG00391

For security measures, the system information that a non-privileged user collects with the fjsnap command is changed.

1.3

Enhanced Support Facility Information Management

PE14127

If the esfadd (bseadd) command failed to install this software, the esfrm (bserm) command fails to remove.

1.2

Web-Based Admin View / WWW Server for Admin View

PE13587

The directory permission of /opt is changed to "755" after installing FJSVwvcnf package.

PE13588

The directory permission of /opt is changed to "755" after installing FJSVwvbs package.

Machine Administration

PE13059

SCF-HALT log is not got in the following conditions when:

  • The SCF-HALT log has been recorded.
  • The log data is saved by using the "Saving the log Data" menu.

PE13708

The fan life is not notified correctly on GP7000F Model 600R.

PE13709

The detailed information of memory configuration error log is not displayed correctly on GP7000F Model 200R.

PE13712

The preventive replacement of memory and U2-cache detected by the POST is not notified.

1.1

*SCF Driver

PF47443

The unit number of the warning message is incorrect when power supply unit failure occurs on Expansion Disk Cabinet and Expansion File Unit.

PF47444

*SCF driver sometimes confuses *SCF HALT for *SCF OFFLINE and *SCF OFFLINE for *SCF HALT.

PF47471

*SCF driver does not report "System Running" after *SCF OFFLINE occurs.

SunVTS,
FJVTS

PE12304

The FJVTS menu becomes abnormal and cannot be operated when the FJVTS in Basic Software Extension 1.1 is invoked on the system where two or more AP-Net cards are mounted.

Web-Based Admin View /WWW Server for Admin View

PE12386

Some applications may terminate on Web Based Admin View in the following situations when:

  • Web Based Admin View is used on Basic Software Extension 1.1.
  • The maximum permitted number of files has been changed on the program that is started on the application in Web Based Admin View.

Machine Administration

PE12208

The tape cleaning monitoring of Machine Administration rewinds the tape medium in the following conditions when:

  • A tape medium is in the tape drive.
  • The tape is not rewound.
  • No process remains opening the tape device.

PE12252

PCI component names in the POST detected error logs are not indicated correctly in the error log display in the following situations when:

  • The lowest two digit of the error code is 0x18, 0x19, 0x1a, 0x1e, 0x1f, or 0x20.

PE12330

The diskswap command fails to append the specified disk to the list of hot-swappable in the following situations when:

  • A failure, which causes the system to fail recognizing the disk occurs (e.g. selection time out).
  • The diskswap command cannot obtain the information of the disk with the iostat(1M) command.

Web-Based Admin View /WWW
Server for Admin View

PE11927

Use of the SynfinityCluster Web-Based Admin View over a long period of time causes the /var/opt partition to fill up.

PE11940

A system sometimes hangs in the shutdown procedure when using Basic Software Extension.

Machine Administration

PE12093

After the FEP hot-swapping by using GUI, the monitoring information of FEP is not automatically reset, and is being left an error.

PE12094

The host selection window of GUI becomes empty after the following procedures:

  • Select the host of "DOWN" status.
  • Press the [Exec] button.
  • Select the [Delete from list] in the displayed dialogue window.

PE12095

In the log information window of GUI, the following error occurs.

  • "All strings match" and "Any of strings match" can be selected at the same time.
  • The operation after displaying the dialogue window is disabled if a wrong value has been specified.

PE12096

The operation is disabled if "08" or "09" has been input at the numerical value input field.

PE12097

The hardware configuration tree is in disorder when the CPU or the SLOT(memory) is "needs maintenance" state.

Auto Power Control System

PE12107

The message "Cluster control configuration management facility is not running." is output to the console in the following situations when:

  • The system is set up for cluster operation.
  • The cluster management has not yet been initialized.
  • The system is booted.

PE12108

The error check for specific days in the schedule is sometimes failed in the following situations when:

  • The schedule is populated with specific days only.
  • The power control has been started (apcsset -S).
  • The status display has been activated (apcsset -L).

License Manager

PE11936

The setup_license command cannot add node locked licenses to the license file if the beginning of hostid characters is 0.

As for the following packages, the patch is automatically applied with the installer.

See the following table 2.2 for details of the bugs and their P-number.

Table 2.2

Package name

Patch ID

P-number

Bug

SUNWvts
SUNWvtsx

912707-01

PG20361

When the pmemtest is executed on the Solaris 8 Operation Environment with kernel patch 108528-16 over, the following message may display; "Unable to read pointer to memlist structure.

FJSVsec

913232-04

PG27531

Output of console stops because softintr was never called.

913233-04

FJSVsnap

914024-01

PG38592

PG38592 Improve functions to decrease the load of the memory during execution.

FJSVdcnf

914006-02

PG38140

The fjcnfset command core dumps during target tape device is busy.

FJSVdr

913732-01

PG40375

The board can't be disconnected once disconnecting board is failed.

PG40559

The error message "-c: not found" was shown during disconnecting board.

PG40560

Improve I/O reference check before disconnecting board.

FJSVmadm

914100-01

PG40732

The function to control the error report is improved.

FJSVcmnd

914099-01

PG40732

The function to control the error report is improved.


Contents Previous

All Rights Reserved, Copyright(C) FUJITSU LIMITED 2004