Enhanced Support Facility 2.5.1 Update Information |
Contents
![]() |
Bugs found in the software of previous version levels are fixed.
See the following table 2.1 for details of the bugs and their P-number.
Table 2.1
Version Level |
Component |
Correction number |
Content of correction or Corrected Bug |
2.5.1 |
Machine Administration |
PG38134 |
The illegal message occurred in the syslog when the memory collectable error is occurred. |
PG38119 |
Improvement of power control with target disk which tries to replace in Hot Swapping Guide. |
||
PG36384 |
The address 0.0.0.0 that means the wild-card, cannot be input in the SNMP Administration menu on PRIMEPOWER250/450. |
||
PG39077 |
The frequency of CPU displayed in Display Hardware Error Log menu is mistaken on PRIMEPOWER650/850. |
||
PG37816 |
Disk information might not be displayed on the hrdconf command on the system which runs Solaris10. |
||
PG37964 |
PCI information is mistaken by the hrdconf command for Solaris9/10 on PRIMEPOWER650/850/900/1500/2500/HPC2500. |
||
PG38179 |
The removable device mark cleared when reset hardware failure at this device by Management of Hardware Error Event menu. |
||
PG39870 |
The PCI card configuration information is wrong in Server System Manager. |
||
Remote Support |
PG37335 |
When the HTTP communication is canceled, the REMCS agent doesn't respond occasionally. |
|
PG39370 |
When the HTTP abnormal connection is repeated, the REMCS agent might not be able to open the file. |
||
PG40322 |
REMCS API does not return rarely. |
||
SunVTS, |
PG36012 |
The fjcputest failed in the floating point unit test. |
|
PG37234 |
When the fjcputest is executed on Solaris 10, the program failed with core dumped. |
||
Server Default Configuration |
PG41048 |
Installation scripts in package, r.manifest and preremove have been modified due to "-C" option had been missing for svcprop(1) in the script. The contents of package except the installation scripts has not been changed. |
|
G-LAN error notification |
PG41520 |
When ESF is installed by the custom jump start,the "Killed" message is displayed by installing the FJSVgidad.us package. |
|
2.5 |
DR command |
PG29523 |
Disconnecting board fails with "Invalid Status Device=Memory Status=NULL." |
NGDR command |
PG28272 |
The board can't be disconnected once disconnecting kernel board is failed. |
|
PG28274 |
Disconnecting board is failed when no-obp-sb is set. |
||
PG28380 |
CPU is still offline after disconnecting board is failed. |
||
SCF driver |
PG33692 |
In the environment by which UPS is connected, the power recovery processing is not correctly done when a momentary power failure occurs, and the system does shutdown occasionally. |
|
PG31442 |
The function of the Fault LED control of extended file unit (PW007FL2/PW007FL2U) is added. |
||
PG29871 |
Group ID of the /opt/FJSVhwr/sbin/fjprtdiag command was changed from 'root' to 'sys. |
||
PG30956 |
In PRIMEPOWER 650/850/900/1500/2500/HPC2500, |
||
PG31447 |
When CPU (SPARV64 V) of 2GHz or more is installed in |
||
PG29396 |
Group ID of the /opt/FJSVhwr/sbin/fjprtdiag command was changed from 'root' to 'sys. |
||
P806854 |
Group ID of the /opt/FJSVhwr/sbin/fjprtdiag command was changed from 'root' to 'sys. |
||
PG31419 |
The function of the Fault LED control of extended file unit (PW007FL2/PW007FL2U) is added. |
||
PG31421 |
When CPU (SPARV64 V) of 2GHz or more is installed, the CPU frequency of the fjprtdiag(1M) command is displayed by a minus value. |
||
Machine Administration |
PG27214 |
Some of mphd driver's error message cannot be detected in PRIMEPOWER650/850/900/1500/2500/HPC2500. |
|
P806678 |
The setrci command dumps core on PRIMEPOWER1/100/200/ 400/600, GP7000F Model200/200R/400/400R/400A/600/600R, FUJITSU S series and GP7000S series. |
||
PG30414 |
A new type of CPU supported. |
||
PG30413 |
The error mark of panic cannot resetted. |
||
PG30412 |
The serial port device information may not display on PRIMEPOWER650/850. |
||
PG30411 |
The memory module failure not reported. if failure memory module mounted on DR-added System board. |
||
PG28416 |
DR may stop by picld restart fail. |
||
PG28417 |
The setrci command may core dumped. |
||
PG28044 |
The CPU mask value display format is wrong on 1560MHz or 1620MHz type SPARC64V. |
||
PG28046 |
The TTY and onboard LAN device is not displayed in configuration display menu on PRIMEPOWER2500/HPC2500. |
||
PG28047 |
The communication between ESF(Enhanced Support facikity) and SCS(System Console Software) is failed on PRIMEPOWER900/1500/2500/HPC2500. |
||
PG27969 |
When the NFS mount to SMC fails, it cannot be judged from the message of PRIMEPOWER900/1500/2500/HPC2500. |
||
PG27111 |
The SCSI-ID of failure unit displayed by hexa-decimal number. |
||
PG27113 |
The Notification to PRIMEPOWER Server Manager when PSU(Power Supply Unit in PCIBOX)exchanged. |
||
PG27114 |
The hardware failure mark vanished when system boot. |
||
PG27117 |
The removable device mark cleared when reset hardware failure at this device. |
||
PG28494 |
The hardware configuration information management Daemon might dump core after executing PCI Hot-plug in PRIMEPOWER450. |
||
PG28496 |
The mark of "(sfdsk)" for the disk managed with SynfinityDisk or PRIMECLUSTER/GDS might not be displayed in hardware configuration information, or the hardware configuration information management daemon might dump core in PRIMEPOWER250/450. |
||
PG28740 |
When the signal is received, the command termination might not be correctly executed on PRIMEPOWER250/450. |
||
PG35532 |
A new message of Solaris 7,8,9 is supported. |
||
PG31493 |
A preventive maintenance and an automatic disk drive power supply off function were supported in Hot Swapping Guide. |
||
PG33902 |
The error mail is notified every about 30 minutes on PRIMEPOWER900/1500/2500/HPC2500 |
||
PG32837 |
The message that the console path was switched might be displayed on the System Management Console on PRIMEPOWER900/1500/2500/HPC2500. |
||
PG33187 |
Spell miss in power log display command on PRIMEPOWER650/850 |
||
PG32037 |
The FAN unit (in RCI-device) failure may be misdetected on PRIMEPOWER900/1500/2500/HPC2500 |
||
PG32038 |
The prterrlog command may displays multiple line of 'VERSION' information. |
||
PG32040 |
The error mark not set when UPS failure detected. |
||
PG32035 |
The CPU and memory statistics information collection function is supported. |
||
PG32036 |
The New menu (Management of Hardware Error Event) supported. |
||
PG32560 |
The PCI card configuration information is wrong in REMCS. |
||
PG32649 |
Spell miss in power log display menu and error log display command. |
||
P806678 |
The setrci command dumps core on PRIMEPOWER1/100/200/400/600, GP7000F Model200/200R/400/400R/400A/600/600R,FUJITSU S series and GP7000S series. |
||
PG33125 |
The hrdconf command does not display the tape device other than "st" in PRIMEPOWER250/450. |
||
PG33369 |
The hcd daemon dumps core in the root directory on PRIMEPOWER250/450. |
||
PG28740 |
When the signal is received, the command termination might not be correctly executed on PRIMEPOWER250/450. |
||
PG28494 |
The hardware configuration information management daemon might dump core after executing PCI Hot-plug in PRIMEPOWER450. |
||
PG28496 |
The mark of "(sfdsk)" for the disk managed with SynfinityDisk or PRIMECLUSTER/GDS might not be displayed in hardwareconfiguration information, or the hardware configuration information management daemon might dump core in PRIMEPOWER250/450. |
||
PG27214 |
Some of mphd driver's error message cannot be detected in PRIMEPOWER650/850/900/1500/2500/HPC2500. |
||
Remote Support |
PG31535 |
The hardware configuration information of new CPU(1.89GHz,2.16GHz) is supported. |
|
PG30430 |
The error generating count of CPU and memory is added to the statistics information notified to a REMCS center. |
||
P806683 |
A software configuration information may not be sent. |
||
P807255 |
HPC downloading function cannot be disabled. |
||
PG36802 |
When the system panic will occur on the PRIMEPOWER650/850, remote.conf file may be broken. |
||
2.4.1 |
NGDR command |
PG20488 |
Support for Dynamic Reconfiguration on PRIMEPOWER 900/1500/2500. |
SCF driver |
PG14495 |
When the GP7000F Model 200/200R/400/400R/400A/600/600R and PRIMEPOWER200/400/600, the Fault LED control of extended file unit (PW007FL2/PW007FL2U) is supported in the diskadm command. |
|
PG22262 |
When the window is closed while executing DR operation from |
||
PG22264 |
In PRIMEPOWER900/1500/2500/HPC2500, the DR operation by the drc command might fail in the system board set in the XSB mode, and the display result of the drcstat command be displayed in the PSB mode. |
||
PG19875 |
There are a lot of memory utilizations of the fjprtdiag command |
||
PG20070 |
When openeepr driver's patch 110918-04 is applied, the |
||
PG18784 |
The display result of fjprtdiag generates the column gap. |
||
PG18852 |
Fjprtdiag command outputs core. |
||
PG22671 |
Correction of fjprtdevice command according to PRIMEPOWER |
||
PG20708 |
Support of PRIMEPOWER250/450 DC model. |
||
PG20365 |
When the PRIMEPOWER250/450, command addition for |
||
PG18863 |
The display result of of fjprtdiag generates the column gap. |
||
PG18864 |
Fjprtdiag command outputs core. |
||
PG20704 |
When the PRIMEPOWER250/450, FANTRAY is made not to be displayed in the SCF driver message in abnormal |
||
PG20706 |
When the PRIMEPOWER250/450, the setting is enabled at the watch time of SCF after it interrupts of REQUEST. |
||
PG20363 |
When the PW250/450, correction of SCF driver according to new addition of SCF support function flag. |
||
PG19874 |
In PRIMEPOWER250/450, when it is reported power failure, power restore, UPS failure, UPS low battery from excluding self device in the RCI composition, the message display is mistaken. |
||
PG19155 |
When the PRIMEPOWER250/450, Ebus time-out is generated by SCF reset. |
||
P805358 |
In PRIMEPOWER1/100, OS panic occurs when the |
||
PG22265 |
When the window is closed while executing DR operation from |
||
PG20050 |
Fjprtdiag command outputs core. |
||
PG20051 |
There are a lot of memory utilizations of the fjprtdiag command |
||
PG20073 |
When openeepr driver's patch 110918-04 is applied, the |
||
PG20336 |
In GP7000F Model 200/200R/400/400R/400A/600/600R and |
||
PG22392 |
The PRIMEPOWER CoD function was supported for |
||
Sunvts, |
4339802 |
disktest fails with multiple instances accessing same parity. |
|
4489875 |
disktest issues a timeout error if fun with multiple instance. |
||
4494434 |
VTS 4.5 device tree lists non-existent ssc100 device. |
||
4508028 |
netlbtest creates a tmpfile in local dir. |
||
4513810 |
ifbtest needs to allow for different sizes of display list memory. |
||
4513580 |
Timed out trying to get a lock on blocks. |
||
4494602 |
disktest on Monterey produces failure. |
||
4532672 |
ifb-lite+ sunvts "segmentation violation" while testing display. |
||
4519508 |
SunVTS 4.5 pmemtest missing ECC report and Section ID |
||
4521847 |
The message that is received when a fan cannister or a power. |
||
4546447 |
sunvts 4.5 ifbtest fails on Serengeti with 4 IFB cards. |
||
4522835 |
Disktest does not achieve a pass with the 12 hrs profile for high |
||
4508863 |
env5test.init_picl_sem.FATAL env /psvc_semaphore failed in |
||
4757224 |
pmemtest fails on systems with Solaris 8 kernel patch 108528-16(KU16). |
||
4641737 |
cputest missing if cpu-id >= 128. |
||
Machine Administration |
PG22765 |
The new mode PRMEPOWER250 4U rack-mount type is supported. |
|
PG21851 |
Improvement of notification e-mail format in |
||
PG21853 |
The REMCS function of extended System Control Facility (XSCF) is supported in PRIMEPOWER250/450. |
||
PG21863 |
When the log directory does not exist, the collection of log fails |
||
PG21864 |
The function to set the hostname of the SMTP server and POP |
||
PG22891 |
The prohibition to invalidate Name Server Administration |
||
PG22892 |
Improvement of the Mail Administration menu of the extended System Control Facility (XSCF) menu in |
||
PG22893 |
Improvement of the error handling process for invalid character inputs on the extended System Control Facility (XSCF) Administration Menus in PRIMEPOWER250/450. |
||
PG22894 |
The extended System Control Facility (XSCF) SSH function is |
||
PG22764 |
Enhancement of the CPU offline function to display the retry out message in PRIMEPOWER250/450. |
||
PG23097 |
When the HCP not supported is registered, an invalid message |
||
PG23082 |
Enhancement of the error message monitoring for the PCI Hot |
||
PG23101 |
The function of the log collection might stop when CPU trouble |
||
PG23213 |
Enhancement of the judgment logic of Standard Console port |
||
PG22961 |
When network products other than TCP/IP are being used, |
||
PG21637 |
When the error of BLASTBAND is detected, an unnecessary message might be displayed on a standard console in |
||
PG21638 |
The save of log data might fail in PRIMEPOWER250/450. |
||
PG22168 |
In PRIMEPOWER250/450, the empty file of a meaningless |
||
PG22228 |
After many hardware error logs occur, hardware error logs |
||
PG22243 |
The hardware configuration information might not be |
||
PG20369 |
Enhancement of the CPU offline function. |
||
PG20370 |
Performance improvement in trace log collection library. |
||
PG20364 |
The file to be saved by the savelogs command might be doubly |
||
PG20366 |
Enhancement of function to detect replacement of unit by check on serial number. |
||
PG20367 |
Enhancement of function which synchronizes with state of unit |
||
PG20368 |
The DC power supply models of PRIMEPOWER250/450 are |
||
PG20373 |
When the error of the I/O device is informed, SCSI-ID of the |
||
PG20349 |
Display order of the selection item is wrong in "Hardware Error Log" menu. |
||
PG20350 |
Enhancement of function to display log in order of time- |
||
PG20351 |
Enhancement of function to refer to detailed log in "Hardware |
||
PG20381 |
Improvement of the firmware update menu. |
||
PG20380 |
Improvement of the condition of HCP update. |
||
PG20378 |
Improvement of the way of collection error (details) log. |
||
PG20384 |
Enhancement of command to update configuration information |
||
PG20385 |
Enhancement of the Hardware configuration display function. |
||
PG20498 |
The command to display the serial number of the server is |
||
PG20511 |
Improvement of the hardware configuration information |
||
PG20436 |
Information is not stored in madmtrace into detail log directory |
||
PG20492 |
Enhancement of the function of the error notification control |
||
PG20464 |
The error report of the disk is not correctly reported. |
||
PG20512 |
Improvement of the order and the item names in the Machine |
||
PG20513 |
Enhancement of the function to operate the CHECK-LED of |
||
PG20514 |
Enhancement of the notification test function. |
||
PG20516 |
Enhancement of the function to collect CPU SK-history log. |
||
PG20518 |
Enhancement of the warning message at the prevention |
||
PG20544 |
The usage message of setfandly command is wrong. |
||
PG20542 |
Enhancement of Automatic Power-on Prohibition Mode after |
||
PG20617 |
The CPU SK-history logs are not collected at the shutdown. |
||
PG20579 |
Improvement of function: When transfer of hardware error log |
||
PG20608 |
An unnecessary detailed log might be displayed in the |
||
PG20610 |
The input of a specific character might not be accepted in the |
||
PG20589 |
The improvement of the extended System Control Facility |
||
PG20629 |
The error message of the scfsnmp command is wrong. |
||
PG20618 |
Can not read the output from child processes. |
||
PG20680 |
Correction of message of "Read-only console" in the extended |
||
PG20681 |
When informing of the error detected by XSCF, the function |
||
PG20682 |
Enhancement of function to control syslog output about the |
||
PG20709 |
The validity check on the address of the SNMP server might |
||
PG20710 |
The same address setting check of the SMTP server might be |
||
PG20718 |
Enhancement of function of PHP in configuration information |
||
PG20719 |
Information of CPU might be wrong in configuration |
||
PG20721 |
When illegal status is read, the hrdconf command dumps the core. |
||
PG20722 |
Improvement of message about the function of the error |
||
PG20909 |
Improvement of message when factor is CPU in Power Log menu. |
||
PG20917 |
Confirmation article of Notification Test is added to the help |
||
PG20818 |
Hardware Error Log might be terminated by program error. |
||
PG20881 |
The hardware error log might not be stored. |
||
PG20984 |
Explanation of unit is added to the help message. |
||
PG20986 |
The status of Machine Administration and XSCF might not be |
||
PG20987 |
In the PRIMEPOWER250 pedestal type, the number of FAN |
||
PG20809 |
Help-documents correction about SNMP setup of SCF |
||
PG20826 |
Internal command error message correction about XSCF |
||
PG20956 |
Help-documents and message correction about XSCF |
||
PG21084 |
In the error notification, the unit number might be wrong. |
||
PG21041 |
The error notification of an environmental error is not |
||
PG21042 |
The notification to the REMCS center might be wrong. |
||
PG21181 |
The processing of the menu might not stop when the RCI |
||
PG19639 |
When configuration information is displayed with the server |
||
PG19669 |
The error of exchanged parts cannot be detected at the hot |
||
PG19681 |
"Error detection stop" command is not reissued when you type |
||
PG19682 |
"FEPFAN status" is displayed in the index of the state column in the "Power Supply Unit of Expansion Cabinet" menu. |
||
PG19683 |
The message in the Hot Swapping menu might cause the mislead that the input of Cancel is recommended than the input of OK. |
||
PG19570 |
The prevention management of miss-configuration of the |
||
PG19672 |
Name change of "Host Name" setup menu. |
||
PG19676 |
Deletion of the function of SNMP access mode selection. |
||
PG19698 |
In the Remote Customer Support System (REMCS) Setup |
||
PG19774 |
The error notification mail and the syslog report is wrong. |
||
PG19809 |
The state of the list after the hot swapping might be different |
||
PG19805 |
The help message of the machine Administration menu is |
||
PG19808 |
The help message of the Power System Administration menu |
||
PG19807 |
The procedure when unmounted parts are section is not |
||
PG19800 |
The longevity of the fan and the battery which the Machine |
||
PG19797 |
In configuration information, detailed information of tape drive |
||
PG19796 |
Updating of configuration information might be slow. |
||
PG19804 |
The user account registered by the extended System Control |
||
PG19680 |
When the addonflush command is executed, the daemon of the |
||
PG19811 |
The help message of the Management of Hardware Error |
||
PG19813 |
The mirroring disk of the Synfinity Disk might not be correctly |
||
PG19783 |
The function to specify and display the XSCF shell access key |
||
PG19784 |
The number of SMTP server and Name server of XSCF |
||
PG19778 |
The help message of the Enable mail Report (and Setup) menu |
||
PG19779 |
An input error is taken again by the re-input after the input |
||
PG19780 |
The user name which is the sub-string of the existent user name can't be added by XSCF user configuration menu. |
||
PG19781 |
A screen transition is incorrect on the setup menu of the SNMP |
||
PG19818 |
A screen transition is incorrect on the setup menu of the Port |
||
PG19819 |
Previously set "Completion time" does not recovered when "q" |
||
PG19867 |
In the Management of Hardware Error Event menu, the fan of |
||
PG19910 |
When Restoring Hardware Monitoring Information is executed |
||
PG18615 |
All users might be able to write the file made by the Machine |
||
PG19289 |
The spelling of "Vendor" is wrong in the hrdconf command. |
||
PG19295 |
Some commands to have permitted a general user to use do not |
||
PG19302 |
The search function of the Management of Hardware Error |
||
PG19303 |
The check on the input character does not work correctly in the |
||
PG19304 |
The longevity notification mail is not transmitted. |
||
PG19305 |
The setpwrmode command displays the setting which are not |
||
PG19308 |
The message in the Hardware Error Log menu is wrong. |
||
PG19311 |
The Setting Monitoring Notification Information menu does not work. |
||
PG19319 |
When information on an abnormality of battery is reset, the |
||
PG19322 |
The error notification mail is not sent to maintenance |
||
PG19334 |
The SMTP server setting is not work correctly in the extended |
||
PG19335 |
The HCP Administration menu changes the SCF bank even if |
||
PG19353 |
The SCF firmware version is not displayed correctly in the |
||
PG19354 |
The CPU information is not displayed correctly in the hrdconf |
||
PG19356 |
The positional information which is informed to XSCF was wrong. |
||
PG19423 |
The mail address and the memo might not be able to input |
||
PG19425 |
The error notification of the RCI node is not displayed |
||
PG19426 |
The status of the FAN and the PSU might not be correctly |
||
PG19427 |
The set object device is not displayed in the Setting the |
||
PG19428 |
The setwarmup command cannot be executed. |
||
PG19429 |
When longevity of the disk and the tape is notified, the error |
||
PG19430 |
The Fault LED is not displayed in the configuration |
||
PG19431 |
When two or more PCI cards with the same driver name and |
||
PG19432 |
The menu might loop infinitely in the extended System |
||
PG19294 |
The error was set both of the PCI card and the hddv device |
||
PG19477 |
When the battery is registered, the longevity is not reflected in |
||
PG19440 |
The configuration change processing loops infinitely when the |
||
PG19444 |
When the correctable error occurred at the UPA bus, the report |
||
PG19429 |
At the error notification or the longevity notification of the |
||
PG19560 |
The error mark set in the past is overwritten at the error |
||
PG19561 |
The log of the error notification of Synfinity Disk cannot be |
||
PG19562 |
The content of the message is improper in the Management of |
||
PG19448 |
A part of temporary file used in the machine administration might not be erased. |
||
PG19442 |
The message notified from SCF were not stored in the machine |
||
PG19473 |
The error log list might be displayed in the Hardware Error |
||
PG19572 |
The item of the subcommand not supported is displayed in |
||
PG19571 |
There is a misprint in usage of setexwait. |
||
PG19573 |
The screen update is too fast after the left count becomes 0 |
||
PG19489 |
When the log of the firmware update history display overflows |
||
PG19529 |
When the Auto-disconnect function of XSCF is registered, the |
||
PG19528 |
The unit of the character is improper in the XSCF |
||
PG19527 |
When the host name is initialized in the Host Name |
||
PG19509 |
After the input is mistaken, the re-input is not correctly |
||
PG19570 |
A standard console cannot be used when switching from the |
||
PG19565 |
When some PCI-CARDs of which the component-name |
||
PG19566 |
The node name of degenerated CPU is not displayed by the |
||
PG19567 |
The cash size of CPU might not be correctly displayed in the |
||
PG19568 |
The error mark might not be added to the degenerated memory |
||
PG19950 |
The function to extract the log file was supported. |
||
PG20387 |
Enhancement of function to display error message in the |
||
PG18684 |
Disk firmware updating fails when the Ultra320 SCSI card is |
||
PG19575 |
PW028SY1 was supported. |
||
PG21929 |
On PRIMEPOWER800/1000/2000, GP7000F Model1000/2000, |
||
P805293 |
On PRIMEPOWER800/1000/2000, GP7000F Model1000/2000, |
||
P805737 |
After a certain period passes, the evsndd daemon dumps core |
||
PG24788 |
PRIMEPOWER650/850 DC power input model supported. |
||
PG24934 |
The normal CPU is offlined on PRIMEPOWER650/850 with |
||
PG24941 |
If the FAN unit failure occurred, Set wrong mark to FEP on |
||
PG24014 |
Check CPU offline function at system boot and each 1hour added. |
||
PG24015 |
Add CPU offline fail message output. |
||
PG24016 |
The memory correctable error message level changed |
||
PG24017 |
The HPC3130 configuration display is wrong on |
||
PG24018 |
The SB(System Board) interleave information is wrong on |
||
PG23831 |
CoD(Capacity on Demand) illegal use message not reported to |
||
PG22907 |
In Cluster environment, When network products other than |
||
PG22622 |
The Console message "_DNFAN not found in |
||
PG22595 |
DN42 file unit supported. |
||
PG22594 |
Even if it makes a System Board configuration change by |
||
PG22295 |
After a certain period passes, the evsndd daemon dumps core |
||
PG22365 |
The empty file of a meaningless name is generated, and |
||
PG22001 |
When network products other than TCP/IP are being used, |
||
PG21543 |
The CPU offline succeed message displayed when offline fail. |
||
PG21137 |
The environment save/restore fail in Live Upgrade. |
||
PG20944 |
The command to display the serial number of the server is |
||
PG20945 |
Enhancement of the function of the error notification control. |
||
PG20946 |
Enhancement of the function of PHP in configuration |
||
PG20947 |
Information of CPU might be wrong in configuration |
||
PG20950 |
Enhancement of command to update configuration |
||
PG20195 |
Cannot connect to stand-by SMC(System Management |
||
PG20048 |
The Hardware Configuration display menu may be fail on |
||
PG20047 |
The cpucomponent command takes long time. |
||
PG19848 |
The hrdconf command takes long time. |
||
PG19349 |
The "Setting Monitoring Notification Information" sub-menu in |
||
PG19235 |
At the time of the unusual detection with unknown Failure |
||
PG19234 |
The display of PCIBOX may not be performed in the hardware |
||
PG18254 |
The setmadmdb command dumps core, when unit entry deleted |
||
PG18040 |
The SPARC64-V peculiar function (kernel message, CPU type |
||
PG22597 |
In GP7000F Model200/200R/400/400R/400A/600/600R, the |
||
PG22380 |
In PRIMEPOWER1/100/200/400/600,GP7000F |
||
Remote Support |
PG21780 |
Periodical connection time might not be displayed in the |
|
PG20806 |
Point-to-Point(VPN) connection is supported. |
||
PG20807 |
Enhancement of the function to do Periodical Connection every |
||
PG20808 |
Save and load of registration data is supported. |
||
PG21054 |
Enhancement of the menu message. |
||
PG21055 |
Enhancement of the help message. |
||
PG21080 |
"Update" is appended to menu which is displayed after load of |
||
PG21164 |
Core file is generated after load of registration data. |
||
PG17213 |
Internet connection (Mail Only) and POP before SMTP are |
||
PG19583 |
The redundant configuration of System Management Console |
||
PG20093 |
The frequency of the CPU of PRIMEPOWER200/400 supports |
||
PG20492 |
Enhancement of the function of the error notification control. |
||
PG20658 |
The multithread unsafe functions are used. |
||
PG21773 |
New feature is appended for REMCS report via XSCF. |
||
PG21842 |
Address and building for the machine are appended to |
||
PG22267 |
When 'q' is selected, next menu displayed is depending on |
||
PG22268 |
Information for user authentication of SMTP is not saved at |
||
PG22284 |
Message improvement. When the setting is invalid, should not |
||
PG22314 |
Some items are written to registration file as #%NUL%# if |
||
PG22520 |
Mail Address is not checked whether it contains '@' in the |
||
PG22601 |
Space character is not accepted for the password. |
||
PG23135 |
Next registration fails when site-server is changed twice. |
||
PG22112 |
Difference of software configuration is not reported until next |
||
PG21767 |
Connection time is not displayed when periodical connection is |
||
PG21300 |
Sender E-mail Address is broken. |
||
PG20396 |
Error message are appended for save and load of registration |
||
PG20427 |
CPU's type, serial number and version are appended to the |
||
PG20468 |
Core file is generated when broken registration data (Length is |
||
PG20636 |
At loading of registration data, data area remains allocated. |
||
PG20637 |
Internal area is broken when length of the name of registration |
||
PG20638 |
Ask (y,n,q) when the registration data can be loaded. |
||
PG20639 |
Improvement of help in the menu of selection of Connection |
||
PG20672 |
Can not read environment data when connection type was |
||
PG20937 |
New feature is appended for everyday periodical connection. |
||
PG20940 |
New feature is appended for save and load of registration data. |
||
PG20942 |
New feature is appended for connection via VPN router. |
||
PG19907 |
PCI Component Name in the machine information is null |
||
PG19914 |
CPU Mask in the machine information is zero. |
||
PG18350 |
Password for user authentication of SMTP is displayed. |
||
PG19547 |
Temporary file is left after package remove. |
||
PG22200 |
The location information of the PCI card in the hardware |
||
PG21819 |
Connection time is not displayed when periodical connection is |
||
PG21301 |
The contents of registration data may break. |
||
PG19219 |
The host name of the host name displayed column of a REMCS |
||
PG20632 |
New feature is appended for everyday periodical connection. |
||
PG20633 |
New feature is appended for save and load of registration data. |
||
PG20634 |
New feature is appended for connection via VPN router. |
||
PG18792 |
The country name in the customer information may be |
||
PG18793 |
There is a security vulnerability of the POP password saving at |
||
PG18827 |
The multithread unsafe functions are used. |
||
PG18829 |
Correction of the CPU type code within the hardware |
||
PG20053 |
Customer information and Environmental setting information |
||
PG21258 |
When the division mail is transmitted with two or more devices at the same time, E-mail might not be able to be received normally at the center. |
||
PG16899 |
Because protocol to which RFC does not conform is used, |
||
Auto Power Control System |
PG21595 |
A Automatic power control on PRIMEPOWER1500/2500 |
|
Server Default |
PG19738 |
SCF might be not informed of system panic in the event of request switch or dump request from the System Console. |
|
Auto Dump |
PG21049 |
The following message might be displayed on the System Console during booting after panic. |
|
Reliability Driver |
PG23541 |
soft interrupt stops, which will stop the console output and |
|
PG20212 |
output of console stops and shutdown will be hung. |
||
PG20231 |
synchronous communication via standard serial port fails. |
||
PG24943 |
If a system board is connected by Dynamic Reconfiguration, |
||
PG25851 |
Disconnetion of the system board by the Dynamic |
||
PG25846 |
If a system board is connected by Dynamic Reconfiguration, |
||
PG25852 |
Disconnetion of the system board by the Dynamic |
||
HCP |
PG23203 |
Patch data corresponding to HCP0501 |
|
2.3 |
Machine Administration |
PG13550 |
The contents of Setting Monitoring Notification Information will be reflected in a Setting Battery Life Notification |
PG13551 |
The add-on detection error message of hddv may be missing |
||
PG13554 |
The Status of ETHERNET#0 on SCFA#0 and ETHERNET#0 on SCFA#1 indicate ALARM when ETHERNET#0 on SCFA#0 error detected |
||
PG13556 |
The setexrdy command fails when external power supply control device (RCIC) in INACTIVE (power off) state. |
||
PG13557 |
The list of RCI devices not updated after RCI network configuration or initial-configuration |
||
PG13558 |
The Domain creation is not permitted from WebSysAdmin |
||
PG13559 |
The PCIBOX connected SB#1 not displayed by hrdconf command |
||
PG13560 |
The notation methods differ [ the check message of FirmUpdate ] in Japanese and English |
||
PG13573 |
On PRIMEPOWER800/1000/2000, GP7000F Model1000/2000, when the partition of the multiprocessor environment boots OS, the evsndd daemon might hangup. Therefore, the boot sequence might stop. |
||
PG13991 |
The RCI address in error message of another node panic is always 0 |
||
PG14128 |
Monitoring the external file unit(PW007FL2/PW007FL2U) was |
||
PG14705 |
The console display message is not compatible to other PRIMEPOWER series. |
||
PG14793 |
Cannot get System Console Software REMCS status from Enhanced Support Facility Machine Administration |
||
PG14794 |
The Disk firmware update by remote host failed |
||
PG14795 |
It guarded so that a prtpwrlog command could be executed only by the model which can operate. |
||
PG14796 |
The getmodelcode command supports all PRIMEPOWER models |
||
PG14797 |
The hardware error log and report log save for 1 entry fails |
||
PG14870 |
The error notification by mail does not work from System Console in the model with a System Console. |
||
PG15042 |
The abnormal temperature monitoring function was supported on |
||
PG15048 |
System boot stop by Machine Administration RC command not return |
||
PG15170 |
The additional kernel message support |
||
PG15171 |
The DDC(DC-DC Converter) type displays at hardware configuration menu and failure messages |
||
PG15436 |
The sfdsk(mphd) message of the failure unit wasn't reported, the wrong driver message of the failure unit reported when the sfdsk(mphd) message and the driver message reported at the same time. |
||
PG15437 |
When the error message of the disk driver is added and monitored, the disk under the control of SynfinityDisk is monitored. |
||
PG15685 |
The all abnormality may not be reported normally when more than one monitoring of abnormality occurred in a short time. |
||
PG15766 |
Fan unit of main cabinet of another host of RCI-connected is observed by monitoring of fan unit of expansion cabinet. |
||
PG15816 |
The getmodelcode command supports new PRIMEPOWER models |
||
PG15817 |
It is not connectable with the standby side in the System Management Console redundantly setup |
||
PG15818 |
The CPU frequency display value of hardware configuration display menu is not correctly |
||
PG15835 |
When the error message of the disk driver is added and monitored, the disk under the control of SynfinityDisk is monitored. |
||
PG15856 |
On PRIMEPOWER800/1000/2000, GP7000F Model1000/2000, The redundant SMC function is supported. |
||
PG17315 |
The sfdsk(mphd) message of the failure unit wasn't reported, the wrong driver message of the failure unit reported when the sfdsk(mphd) message and the driver message reported at the same time. |
||
PG17316 |
On PRIMEPOWER800/1000/2000, GP7000F Model1000/2000, information is sent only to Service SMC in the Hot Spare SMC. |
||
PG17319 |
On PRIMEPOWER800/1000/2000, GP7000F Model1000/2000, when the command by which SMC is set is executed, it executes the shareall command. |
||
PG17324 |
On PRIMEPOWER800/1000/2000, GP7000F Model1000/2000, the hrdconf command might display wrong information on a disk. |
||
Remote Support |
PG13058 |
Software configuration information may not be sent to REMCS center. |
|
PG13315 |
The Periodical Connection may not be made. |
||
PG13317 |
An error code may not be displayed on the error message at the failing time of connection check. |
||
PG13318 |
Statistics information may not be notified. |
||
PG13319 |
The error output of a "cat" command may be displayed on the console. |
||
PG13932 |
The registration may be failed and a core file is created at the root directory. |
||
PG14677 |
The REMCS reported message is not compatible to other PRIMEPOWER series. |
||
PG15554 |
Can not registration from Management Server. |
||
PG15767 |
The mistake might be found in information on next Periodical Connection Schedule of Periodical Connection event information to the REMCS Center. |
||
PG15768 |
The mistake might be found in information on code of customer information to the REMCS Center. |
||
PG18593 |
The mistake might be found in information on code of customer information to the REMCS Center. |
||
Crash Dump Assistant |
P804853 |
Access is impossible from a client node to a share file system after Execution of the fjdmpadm and scslset commands. |
|
CPU Patrol |
PG13776 |
An unnecessary message may be displayed when the LANG environment variable is "ja" on Solaris 9 OS. |
|
2.1 |
Web-Based Admin View / WWW Server for Admin View |
PG10309 |
Menu which cannot be selected exists even if user logins as wvroot group. |
PG10310 |
Command execution processing may stop in JavaVM. |
||
PG10311 |
Phraseologies different from other screen on Environment setup screen is corrected. |
||
PG12175 |
When an illegal request was sent while connecting with WWW Server for Admin View, the content of the displayed error message is wrong. |
||
*SCF driver |
PG10648 |
When abnormality such as FAN/FEP occurs with the external unit such as FDE connected on RCI, neither the part name nor the part number are output to *SCF driver's WARNING message. |
|
PG11623 PG11723 |
Scfctlbrk command support. |
||
SunVTS,FJVTS |
PG12533 |
When there is a cpu which status is "no-intr", the FJVTS will be core dumped by invoking it. |
|
PG12314 |
The machine administration hardware configuration display of PCI disappears PP028GE1 or PW008QE1 at PP028GE1 and PW008QE1 both installed system. |
||
PG12316 |
The Machine Administration error report message might not point out the failure unit. |
||
Remote Support |
PG11806 |
A software event may not be sent to REMCS center. |
|
License Manager |
P803908 |
When the name service has stopped, the license manager is started or stopped slowly. |
|
Reliability Driver |
PG12200 PG12694 |
The drc command stops on the connection script FJSVse and doesn't return. |
|
P804182 |
"WARNING: interrupt level 4 not serviced" is displayed. |
||
2.0 |
*SCF driver |
P803604 |
When X1141A card is installed, and "drcstat -device" is executed, the device of hme and ge might be displayed duplicatede. |
Machine Administration |
PG10380 |
The machine administration misunderstands FAN/FEP mounting data on PRIMEPOWER650 and 850. |
|
PG10382 |
The Hardware error information is not set at FAN/FEP/PCIBOX on PRIMEPOWER650 and 850. |
||
PG10383 |
Error indication of PCIBOX displays another PCIBOX on PRIMEPOWER850. |
||
PG10384 |
Error indication of PCIBOX can not be disappeared after it maintained on PRIMEPOWER650 and 850. |
||
PG10405 |
User who is not belonging to the root group can't display "Hardware Configuration" in the CUI menu. |
||
PG10580 |
Error indication of FAN/FEP can not be disappeared after it maintained on PRIMEPOWER650 and 850. |
||
P803654 |
The herdconf command may display incorrect hardware composition after changing the system configuration by Dynamic Reconfiguration. |
||
Auto Power Control System |
PG09849 |
Warning message three minutes before the shutdown may not be displayed. |
|
1.8 |
*SCF driver |
P803424 |
Even if a UPS is reconnected after momentary power failure,it is likely to be shutdown. |
SunVTS, |
PG07857 |
When the fjswutest is executed, a core dump may be generated. |
|
Machine Administration |
PG06692 |
The hrdconf command dumps core when the system has many disk instances. |
|
PG06714 |
The hrdconf command dumps core when the system has many disk instances. |
||
PG06724 |
When an abnormal report to the REMCS center happens frequently, |
||
PG06904 |
On PRIMEPOWER1/100/200/400/600 and GP7000F Models 200/200R/400/400R/400A/600/600R, a message that is not the watch object is observed. |
||
PG07158 |
The Machine Administration might generate an incorrect message error , when two or more messages occur at the same time. |
||
PG07201 |
A fibre channel card error might not be generated. |
||
PG07202 |
The Machine Administration might generate an incorrect error message, when two or more messages occurred at the same time. |
||
PG07214 |
A fibre channel card error might not be generated. |
||
PG07540 |
When abnormality occurs in the main Cabinet FAN, an unnecessary message of "test: argument expected" is displayed on the console. |
||
PG07653 |
The hrdconf command displays "GP7000F" as the series name for PRIMEPOWER800/1000/2000 when the product ID starts with "PW". |
||
PG08308 |
The Machine Administration may inform of a panic though kernel does not panic. |
||
PG07909, PG08309 |
The Machine Administration displays a normal disk as in error, when the RAID controller of the other path fails. |
||
Remote Support |
PG06589 |
The menu screen of Software Investigation Information Collection is corrupted. |
|
PG06721 |
A mistake is found in the abnormal report format sent to the REMCS center. |
||
PG06723 |
HW configuration data to which the CD-ROM configuration is changed when the disk configuration is changed might be notified to the REMCS center. |
||
PG06727 |
After setting of REMCS environment, an Http Proxy password may become invalid.. |
||
PG06772 |
When Remote Setup menu is executed in an English environment, a mistake is found in the displayed message. |
||
PG06917 |
Temporary file sometimes found in root directory when connection confirming failed. |
||
PG07046 |
Periodical Connection Time is not correctly set when setting or changing Periodical Connection Time on the change day for summer time/daylight saving. |
||
PG07536 |
A mistake might be found in information on FEP or FAN of HW configuration data notified to the REMCS center when a FEP or FAN abnormality occurs. |
||
PG07537 |
A mistake might be found in information on the memory of HW configuration data notified to the REMCS center. |
||
PG07538 |
A mistake might be found in information on the CPU of HW configuration data notified to the REMCS center. |
||
PG07539 |
Information on DISK of HW configuration data notified to the REMCS center might be missed. |
||
System Data Output Tool |
P803159 |
Information output by prtdiag command might not be collected. |
|
Reliability Driver |
PG05363 |
In a system in which the console path is made redundant, if a change occurs due to path abnormalities , the console display under reboot will not be carried out. |
|
1.7.1 |
Machine Administration |
PG05054 |
An unnecessary message might be displayed on the console after the system panics. |
PG05154 |
The part of the message that indicates possible error locations (SCSI ID) may be incorrect in the tape cleaning notification. |
||
PG05163, PG05250 |
When you terminate the terminal or log out while running the Machine Administration menu, the menu loops in the background for awhile, in some cases, a core dump might be generated. |
||
PG05164, PG05255 |
When an error message is detected continuously on the same kind of I/O devices, the Machine Administration may not identify the unit correctly. |
||
PG05165 |
When system time is changed by the date command, the evsndd cannot communicate with a System Management Console normally. |
||
PG05166 |
When the evsndd is started multiple times, a core dump is generated. |
||
PG05056 |
Moving a tag on the Machine Administration GUI menu may cause the GUI menu to enter an abnormal state. |
||
PG05254, PG05641, PG05646 |
The Machine Administration GUI menu might terminate abnormally when characters such as "!" , "(", and "=" are input. |
||
PG05642 |
Typographical errors may not be pointed out even if a nonexistent character string is input on the Machine Administration CUI menu. |
||
PG05643 |
The evsndd might not inform the system administrator of its status by mail when cutting communication with a System Management Console. |
||
Remote Support |
PG05490 |
An error message may not be reported to Fujitsu Support Center even in the case of a system panic. |
|
1.7 |
Machine Administration |
PG04395 |
An unnecessary message might be displayed on the console. |
1.6 |
*SCF Driver |
PG00679 |
*SCF driver does not control twenty four or more RCI devices. In this case, the rciinfo command indicates "0" to each subsequent RCI device. |
SunVTS, |
PG02477 |
The fjvts command cannot be executed on Enhanced Support Facility 1.5 or 1.6 in the following conditions when:
|
|
Machine Administration |
PG02568 |
The error message displayed on the console does not have a device name when device degradation occurs during system initialization. |
|
PG02570 |
The Machine Administration does not detect a single-bit memory error on PRIMEPOWER1. |
||
PG02567 |
When using Saving the Log Data, the message "Hit return key" is displayed twice. |
||
PG02596 |
The prtpwrlog command returns the value other than "0" even if the command has completed successfully with the -x option. |
||
PG02374 |
When using Saving the Log Data, the message "The file has already exist " is displayed twice if the file name already existed. |
||
PG02435 |
When using Saving the Log Data, specifying a file name with a relative path name causes to save the file is relative to the root. |
||
PG02276 |
On PRIMEPOWER and GP7000F Models 200R/400R/400A, the abnormal state of the CPU degradation displayed in the Hardware Configuration of Machine Administration is not reset even though the system is rebooted. |
||
PG01956, PG02484 |
The guidance "To specify more than one, use a comma to delimit the number such as 1,2." displayed on the menu is incorrect when using Saving the Log Data. |
||
PG01957, PG02487 |
An unreadable message is displayed on the Disk Firmware Administrator Menu when an error occurs. |
||
PG02274, PG02485 |
Even though an incorrect parameter is input, the subsequent steps request you to input the file name you want to save when using Saving the Log Data. |
||
PG01863, PG01857 |
The hardware error is not notified even if it occurs on the array disk unit (GR730 or GR740). |
||
PG02280 |
Some of *SCF error codes may not be recorded in the Power Error Log. |
||
PG02130, P802357 |
Depending on the timing of cutting and reconnecting, the "DOWN" state may be displayed on the host selection window of GUI even if the node is normal. |
||
PG01953 |
The items and the contents that indicate the battery status and life have reversed on the Adding Battery Life Information of GUI. |
||
1.5 |
Machine Administration |
PG00766 |
The menu or the command usage represented on the display is incorrect. |
PG00767, PG00771 |
Machine Administration does not detect any error message related to the new SCSI adapter device(LVD). |
||
PG00768 |
The RCI address may be set to the initial value on the host selection window of Machine Administration even if it has been set. |
||
PG00769 |
Letters for "ErrorCode:0x8046000" are not displayed on the *SCF error log display of Machine Administration. |
||
PG00924, PG00989 |
The hardware error is not notified immediately even if the kernel and driver error messages are detected. In the event of shutting down the system, the kernel and driver error messages may be lost. |
||
PG00933 |
In the monitoring of disk, tape unit, fan, power supply unit, and battery life, all of their information may not be notified even if two or more units are under the report conditions. |
||
PG00851, PG00850 |
The degradation of the array disk unit (GR720) components is not reported. |
||
PG00951, PG01248 |
The top menu does not appear when "t" is selected on the Disk Firmware Administrator Menu of Machine Administration. |
||
PG00999, PG00925 |
Some configuration data is not restored when Enhanced Support Facility is reinstalled. |
||
PG01029, PG00977 |
The date based searches are not performed correctly when date condition is specified two or more times on the CUI Log Data Menu of Machine Administration. |
||
PG01088, PG00976 |
The part of the message that indicates possible error locations may be incorrect when the WAN adapter error occurs. |
||
PG01114, PG00975 |
The setpwrmode command confuses EPCREIPL and POFFRCV when displaying and setting EPCREIPL. |
||
PG00766, PG01271 |
Wrong message is displayed on the Machine Administration menu and command usage. |
||
PG01234, PG01272 |
The syslogd error message may be displayed when shutting down the system. |
||
PG01236, PG01273 |
The host name may not be displayed on the Host Selection window of the Machine Administration GUI menu after updating Enhanced Support Facility. |
||
PG01008 |
The function for setting up IPL signal of RCIC that is not supported on the unit can be available by using the Machine Administration menu and commands. |
||
PG01025 |
Illegal characters may be displayed on the power log display of Machine Administration. |
||
PG01096 |
"Saving the log Data" on the Machine Administration CUI menu becomes abnormal. |
||
PG01188 |
The following file may remain illegally even if Machine Administration has been uninstalled./opt/FJSVmadm/lib/regist.bin.bak |
||
PG01191 |
The part of the message that indicates possible error locations may be incorrect when a SynfinityDisk error is detected. |
||
PG01192 |
The power supply unit fan (FEPFAN) that is monitored by the Machine Administration is displayed with a maximum delay of 24 hours. |
||
PG01220 |
Reset of tape unit monitoring information and setting of tape unit monitoring notification cannot be made on the Machine Administration menu. |
||
PG01263 |
The hot-swapping of FAN#14 cannot be made on PRIMEPOWER400. |
||
P802362 |
The evsndd daemon may output a core dump if the communication with System Management Console failed on PRIMEPOWER800/1000/2000 and GP7000F Models 1000/2000. |
||
P802347 |
The shutdown command may be ineffective if the communication with System Management Console failed on PRIMEPOWER800/1000/2000 and GP7000F Models 1000/2000. |
||
PG01247 |
The power supply linkage mode that is not supported on PRIMEPOWER800/1000/2000 and GP7000F Models 1000/2000 can be set. |
||
System Data Output Tool |
PG00799 |
The fjsnap command may be executed while it is being executed. |
|
License Manager |
P802190 |
FLEXlm license daemon sometimes fails to start when the node name takeover of 1:1 standby is set with SynfinityCluster system. |
|
1.4 |
*SCF Driver |
PE14351 |
*SCF driver shuts down a system when a permanent error of *SCF hardware/firmware occurs. |
SunVTS, |
PE14523 |
The following error related to the semaphore occurs while the fjbcdrtest or fjwpcdtest commands is running for a long period of time. |
|
Web-Based Admin View / WWW Server for Admin View |
PG00532 |
The system status may become abnormal or the correct data for investigation may not be collected in the following conditions when: |
|
Machine Administration |
PE14273 |
Machine Administration sometimes continues the increasing of management log files infinitely. |
|
PE14484 |
The actual system condition is not displayed correctly on the power log display. |
||
PE14534 |
The hard disk hot-swapping may not be made. |
||
PE14608 |
In the hardware monitoring information notification setting, the display of the notification destination has reversed in the English mode. |
||
PG00302 |
Because the tape cleaning monitoring of Machine Administration conflicts with the tape device opening of another application during system start-up, the application may terminate abnormally. |
||
PG00303 |
The errors may be displayed on the console once every 24 hours when a RAID device is connected. |
||
PG00304 |
The serial number of the disk is not displayed in the hardware configuration display. |
||
PG00305 |
There is no message on the memory information display menu even when the memory error occurs. |
||
PG00320 |
FAN#12 or FAN#13 seem to not be mounted on GP7000F Models 400A and 400R in the configuration information notified the REMCS center. |
||
PG00332 |
On GP7000F Models 200, 200R, 400, 400R, 400A, 600, and 600R, the REMCS agent menu terminates abnormally in the following conditions when:
|
||
PG00370 |
The hardware error is not notified even if it occurs on the hddv disk connected with the fiber channel. |
||
PG00410 |
In the fan life monitoring, FEPFAN which does not exist on GP7000F Model 200 is added. |
||
PG00412 |
The Power Recovery Mode setting by the setups command is not validated. |
||
PG00419 |
Unusual behavior may be caused by inputting a special character string in the REMCS agent menu. |
||
PG00420 |
The message of the report mail by which the error is detected by SynfinityDisk becomes abnormal. |
||
PG00485 |
The Machine Administration menu terminates abnormally when a character string containing a space character is input into a field on the top menu. |
||
PG00487 |
Battery or fan information can be registered by the setbattlife or setfanlife commands even if the identification number is not specified. |
||
PG00488 |
The setpwrmode command fails to display the state of EPCREIPL. |
||
P801826 |
When the prtmsglog command is executed, a core dump may be generated. |
||
Auto Power Control System |
P801928 |
When the environment variable "LC_ALL" or "LC_MESSAGES" is set, Auto Power Control System sometimes fails to set the shutdown schedule. |
|
P801941 |
When cron daemon has been stopped, Auto Power Control System respons no error while you set the schedule. |
||
System Data Output Tool |
PG00391 |
For security measures, the system information that a non-privileged user collects with the fjsnap command is changed. |
|
1.3 |
Enhanced Support Facility Information Management |
PE14127 |
If the esfadd (bseadd) command failed to install this software, the esfrm (bserm) command fails to remove. |
1.2 |
Web-Based Admin View / WWW Server for Admin View |
PE13587 |
The directory permission of /opt is changed to "755" after installing FJSVwvcnf package. |
PE13588 |
The directory permission of /opt is changed to "755" after installing FJSVwvbs package. |
||
Machine Administration |
PE13059 |
SCF-HALT log is not got in the following conditions when:
|
|
PE13708 |
The fan life is not notified correctly on GP7000F Model 600R. |
||
PE13709 |
The detailed information of memory configuration error log is not displayed correctly on GP7000F Model 200R. |
||
PE13712 |
The preventive replacement of memory and U2-cache detected by the POST is not notified. |
||
1.1 |
*SCF Driver |
PF47443 |
The unit number of the warning message is incorrect when power supply unit failure occurs on Expansion Disk Cabinet and Expansion File Unit. |
PF47444 |
*SCF driver sometimes confuses *SCF HALT for *SCF OFFLINE and *SCF OFFLINE for *SCF HALT. |
||
PF47471 |
*SCF driver does not report "System Running" after *SCF OFFLINE occurs. |
||
SunVTS, |
PE12304 |
The FJVTS menu becomes abnormal and cannot be operated when the FJVTS in Basic Software Extension 1.1 is invoked on the system where two or more AP-Net cards are mounted. |
|
Web-Based Admin View /WWW Server for Admin View |
PE12386 |
Some applications may terminate on Web Based Admin View in the following situations when:
|
|
Machine Administration |
PE12208 |
The tape cleaning monitoring of Machine Administration rewinds the tape medium in the following conditions when:
|
|
PE12252 |
PCI component names in the POST detected error logs are not indicated correctly in the error log display in the following situations when:
|
||
PE12330 |
The diskswap command fails to append the specified disk to the list of hot-swappable in the following situations when:
|
||
Web-Based Admin View /WWW |
PE11927 |
Use of the SynfinityCluster Web-Based Admin View over a long period of time causes the /var/opt partition to fill up. |
|
PE11940 |
A system sometimes hangs in the shutdown procedure when using Basic Software Extension. |
||
Machine Administration |
PE12093 |
After the FEP hot-swapping by using GUI, the monitoring information of FEP is not automatically reset, and is being left an error. |
|
PE12094 |
The host selection window of GUI becomes empty after the following procedures:
|
||
PE12095 |
In the log information window of GUI, the following error occurs.
|
||
PE12096 |
The operation is disabled if "08" or "09" has been input at the numerical value input field. |
||
PE12097 |
The hardware configuration tree is in disorder when the CPU or the SLOT(memory) is "needs maintenance" state. |
||
Auto Power Control System |
PE12107 |
The message "Cluster control configuration management facility is not running." is output to the console in the following situations when:
|
|
PE12108 |
The error check for specific days in the schedule is sometimes failed in the following situations when:
|
||
License Manager |
PE11936 |
The setup_license command cannot add node locked licenses to the license file if the beginning of hostid characters is 0. |
As for the following packages, the patch is automatically applied with the installer.
See the following table 2.2 for details of the bugs and their P-number.
Table 2.2
Package name |
Patch ID |
P-number |
Bug |
SUNWvts |
912707-01 |
PG20361 |
When the pmemtest is executed on the Solaris 8 Operation Environment with kernel patch 108528-16 over, the following message may display; "Unable to read pointer to memlist structure. |
FJSVsec |
913232-04 |
PG27531 |
Output of console stops because softintr was never called. |
913233-04 |
|||
FJSVsnap |
914024-01 |
PG38592 |
PG38592 Improve functions to decrease the load of the memory during execution. |
FJSVdcnf |
914006-02 |
PG38140 |
The fjcnfset command core dumps during target tape device is busy. |
FJSVdr |
913732-01 |
PG40375 |
The board can't be disconnected once disconnecting board is failed. |
PG40559 |
The error message "-c: not found" was shown during disconnecting board. |
||
PG40560 |
Improve I/O reference check before disconnecting board. |
||
FJSVmadm |
914100-01 |
PG40732 |
The function to control the error report is improved. |
FJSVcmnd |
914099-01 |
PG40732 |
The function to control the error report is improved. |
Contents
![]() |