Top
ServerView Resource Orchestrator Cloud Edition V3.1.0 User's Guide for Infrastructure Administrators (Resource Management)

5.10 Registering Power Monitoring Devices

This section explains how to register power monitoring devices.

Registering power monitoring devices (PDU or UPS) enables monitoring of power consumption.

Use the following procedure to register power monitoring devices.

  1. In the ROR console power monitoring device tree, right-click [Power Monitoring Devices] and select [Register]-[Power Monitoring Device] from the popup menu.

    The [Register Power Monitoring Device] dialog is displayed.

  2. To use this feature, the following settings must first be defined:

    Device name

    Enter a name to assign to this power monitoring device. When exporting power consumption data, use this name to select power monitoring devices for which to export data.
    Enter a character string beginning with an alphabetical character and containing up to 15 alphanumeric characters and hyphens ("-").

    Admin LAN (IP address)

    Enter the IP address that was set on this power monitoring device. This IP address will be used to collect power consumption data from this power monitoring device.

    SNMP Community

    Enter the SNMP community that was set on this power monitoring device.
    Either select [public] or enter an arbitrary string.
    Enter a string of up to 32 alphanumeric characters, underscores ("_"), and hyphens ("-").
    This SNMP community will be used to collect power consumption data from this power monitoring device (via SNMP protocol).

    Voltage

    Enter the voltage (V) supplied to this power monitoring device. Enter a number between 10 and 999. Power consumption data is calculated using the electrical current value obtained from this power monitoring device and its specified voltage.

    Comments

    Enter a comment that describes this power monitoring device.
    Enter up to 128 alphanumeric characters or symbols (ASCII characters 0x20 to 0x7e).

    Note

    A line break is counted as one character.

  3. Click <OK>.

    The registered power monitoring device will be displayed under the power monitoring devices tree.

If collection of power data is disabled in the option settings, data will not be collected even if power monitoring devices are registered. Change power data collection settings according to "7.8.1 Changing Environmental Data Settings".

Note

Resource Orchestrator is not aware of the relationship between power monitoring devices and actual server resources. Make sure to register the power monitoring devices that are connected to the server resources for which you want to monitor power consumption.